Patton electronic SmartNode 4110 Series manual Configuring the traffic class for H.323 signaling

Models: SmartNode 4110 Series

1 664
Download 664 pages 15.88 Kb
Page 556
Image 556

SmartWare Software Configuration Guide

45 • H.323 gateway configuration

 

 

Changing the TCP port for inbound call-signaling connections

The default TCP listening port for inbound call-signaling connections is per default 1720 as defined in the H.323 standard. The following procedure describes how to change the port number.

Mode: Gateway H.323

Step

1

Command

Purpose

 

 

node(gw-h323)[h323]#call-signaling-port

Define the TCP port to use for inbound call-sig-

port

naling connections

 

 

Example: Defining an alternate call-signaling port

The following example shows how to define an alternate call-signaling port on an already defined H.323 Gate- way.

node(cfg)#gateway h323 h323 node(gw-h323)[h323]#call-signaling-port 1721

Configuring the traffic class for H.323 signaling

The traffic class for H.323 signaling is configurable. The configured traffic class is used as additional routing criterion in the IP routing table.

Mode: Gateway H.323

Step

Command

Purpose

 

 

 

1

[ name] (gw-h323)[gateway]# call-signal-

Sets traffic class for H.323 signaling packets.

 

ing-trafficclass <traffic-class>

The traffic class may be new or may already

 

 

exist.

 

 

 

Setting the response timeout

Per default the H.323 gateway waits for 12s from the time it initiated a call towards the IP network until it ter- minates the call, if no response has been received. This time can be changed using the following procedure:

Mode: Gateway H.323

Step

1

Command

Purpose

 

 

node(gw-h323)[h323]# timeout response

Defines the response timeout in seconds.

seconds

 

 

 

Example: Defining an alternate response timeout

The following example shows how to define an alternate response timeout of 6 seconds on an already defined H.323 Gateway.

node(cfg)#gateway h323 h323 node(gw-h323)[h323]#timeout response 6