SmartWare Software Configuration Guide40 • Call router configuration

node(rt-tab)[TEST]#route default dest-interface IF5 node(rt-tab)[TEST]#exit node(ctx-cs)[switch]#no shutdown node(ctx-cs)[switch]#debug call-router detail 5

node(ctx-cs)[switch]#test call-router TEST called-e164 123 Parameters

==========

Time:

 

 

2004-03-02T16:55:33<-- Time of the lookup

Result:

 

 

route-found-place-call<-- Lookup result

Destination:

 

IF2<-- Dest. Interface

Timeout:

 

 

0<-- Digit-Coll. TO

Property Containers

 

-------------------

 

Properties

 

 

Properties

 

 

E164-Number:

123 (String)<-- CdPN after lookup/change

Properties

 

 

16:55:33

CR

> [switch] Routing-Lookup:

16:55:33

CR

> Find best-matching called-element in table test

16:55:33

CR

>

01: Prefix Timeout Expression: E164-Number of 123 completely

(no timeout)

matches 1

16:55:33

CR

>

02: Prefix Timeout Expression: E164-Number of 123 completely

(no timeout)

matches 1[0-4]

16:55:33

CR

>

03: Prefix Timeout Expression: E164-Number of 123 does not

match 11

 

 

 

16:55:33

CR

>

04: Prefix Timeout Expression: E164-Number of 123 does not

match 111

 

 

 

16:55:33

CR

>

Selecting entry 2

16:55:33

CR

> Execute all elements in table IF2

16:55:33

CR

> Execute all elements in table route-found-place-call

16:55:33

CR

>

Lookup result: Route found; place call (timeout=0)

Call router configuration task list

516

Page 516
Image 516