Patton electronic SmartNode 4110 Series Debugging H.323 Signaling, Overview H.323 debug monitors

Models: SmartNode 4110 Series

1 664
Download 664 pages 15.88 Kb
Page 634
Image 634

SmartWare Software Configuration Guide

52 • VoIP debugging

 

 

09:14:02 CFXS > [EP PHONE] Change state to CONNECTED.: The phone went off-hook and thus accepted

the call. The state of the CS interface goes to CONNECTED. The call is now established.

Debugging H.323 Signaling

Overview: H.323 debug monitors

 

Command

Purpose

 

 

 

 

unit#debug gateway h323 signaling

Prints all signaling operations on H.323 interfaces.

 

 

 

 

unit#debug gateway h323 error

General purpose error monitor of H.323. Always

 

 

enable this when debugging H.323.

 

 

 

 

unit#debug gateway h323 datapath

Prints operations on the H.323 part of the voice

 

 

data path. Use this monitor if you experience prob-

 

 

lems in the data path (no speech connectivity,

 

 

speech only in one direction). This monitor is not

 

 

needed to debug signaling.

 

 

 

 

unit#show gateway h323 status

Shows the state of the H.323 gateway. Among

 

 

others: enabled/disabled, RAS registration state.

 

 

 

 

unit#show gateway h323 call name

Shows all calls ongoing on the H.323 interface on

 

[detail detail]

context CS with name name.

 

 

 

 

unit#show call-control provider name

Shows the status of an H.323 interface in context

 

[detail detail]

CS (call control part of H.323 signaling). Shown

 

 

are all calls currently ongoing on the interface,

 

 

with their call states, signaling peers and voice

 

 

data path parameters.

 

 

name is the name of the H.323 interface. Use

 

 

detail 5 for most verbose output.

 

 

 

See also section “Troubleshooting” on page 558 for further informations on debugging H.323. There are more than 40 debug monitors, such as q931, ras, or signaling. For a list of all available debug monitors, refer to the CLI online help.

Verify an incoming call

Make sure an incoming call is entering correctly context CS. In this example, a VoIP gateway or VoIP phone on the network makes a call to your unit using a gatekeeper. The debug output below shows a normal (work- ing) call setup sequence

unit#enable

unit#configure

unit(cfg)#debug gateway h323 error unit(cfg)#debug gateway h323 signaling unit#debug gateway h323 ras unit(cfg)#show gateway h323 status H.323 Gateway: h323

===================

State:

UP

Stack Handle:

0x193ce44

RAS Engine

 

Debugging call signaling

634

Page 634
Image 634
Patton electronic SmartNode 4110 Series manual Debugging H.323 Signaling, Overview H.323 debug monitors