SmartWare Software Configuration Guide

31 • CS context overview

 

 

Mode: System

Step

Command

Purpose

 

 

 

1

node(sys)#clock-source hw-type slot port

Add an entry to the end of the list

 

 

 

 

node(sys)#clock-sourceindex hw-type slot port

Overwrite and entry at position ‘index’

 

 

 

 

node(sys)#clock-source before index hw-type slot port

Insert an entry before position ‘index’

 

 

 

 

node(sys)#clock-source after index hw-type slot port

Insert an entry after position ‘index’

 

 

 

 

node(sys)#clock-source index up positions

Move entry at ‘index’ number of ‘posi-

 

 

tions’ up

 

 

 

 

node(sys)#clock-source index down positions

Move entry at ‘index’ number of ‘posi-

 

 

tions’ down

 

 

 

Debugging the clock source

To control the system behaviour at runtime, there exists a debug command with the options ‘event’ and ‘error’. If the user enables the ‘event’ command, he can follow the system’s Clock Source Hunting algorithm, the out- put informs about the occurrence of a clock source change. In addition exists a ‘show’ command that prints the clock source configuration and marks the ports that are synchronized. Further, the port that has been chosen by the system as the current clock source will also be displayed.

Mode: Operator execution

Step

Command

Purpose

 

 

 

1

node#[no] debug system-clock {event error}

Enables/Disables the system clock moni-

 

 

tor

 

 

 

Mode: Operator execution

 

 

 

 

Step

Command

Purpose

 

 

 

1

node#show system-clock

Print system clock information

 

 

 

node#show system-clock

Current clock source

====================

t1 0 2 0

Registered clock sources

========================

Name

 

 

Sync

e1

0

1 0

 

t1

0 2 0

X

bri 0 3 0

 

bri 0 3

1

 

bri 0 3

2

 

bri 0 3

3

 

internal

X

Configuring general CS settings

344

Page 344
Image 344