SmartWare Software Configuration Guide

40 • Call router configuration

 

 

Caveat: For calls from the IP side, the service only works if the G711.alaw codec is chosen. On the SmartNode 4960 the service is available for all configurable codecs.

Mode: Context CS

Step

Command

Purpose

 

 

 

 

 

1

node(ctx-cs)[switch]#service second-

Enters the service second-dialtone mode.

 

dialtone name

 

 

 

 

2

node(svc-2dt)[name]#route call dest-

Defines the call destination. If the call cannot be placed the

 

interfacedest-servicedest-table

second-dialtone is played.

 

name

 

 

 

 

3

node(svc-2dt)[name]#route

Instead of playing a dialtone locally, the service sets up a call

 

announcement dest-inter-

to the configured message provider.

 

facedest-servicedest-table

 

 

name

 

 

 

 

4

node(svc-2dt)[name]#use profile

Apply to use a alternative tone-set profile. If not configured

 

tone-set name

the profile tone-set default will be used.

 

 

 

Deleting call services

To remove individual call services you can use the no form of the service command.

Procedure: To delete a call service

Mode: Context CS

Step

1

Command

Purpose

 

 

node(ctx-cs)[switch]#no service service-

Delete the service service-name.

name

Note: You do not have to enter the type of the service when

 

 

just deleting it. The type must only be specified when creating

 

a service.

 

 

Example: Remove an entire mapping table

node(cfg)#context cs node(ctx-cs)[switch]#no service HUNT-BRI

Activate the call router configuration

Prior to activate the call router configuration you can show the whole context CS configuration and the entire call routing tables.

The call router configuration is activated as soon as the CS context comes out of shutdown (e.g. at boot time or by manually entering command no shutdown). You can modify the configuration at runtime; changes will be active after 3 seconds. SmartWare offers a number of possibilities to monitor and debug the CS context and call router configurations. For more information refer to chapter 52, “VoIP debugging” on page 624.

Note It is not necessary to shutdown the CS context prior to making any configu- ration changes.