Patton electronic SmartNode 4110 Series manual Dial-up on demand

Models: SmartNode 4110 Series

1 664
Download 664 pages 15.88 Kb
Page 337
Image 337

SmartWare Software Configuration Guide

30 • PPP configuration

 

 

interface dialer IF_DIALUP

outbound 1 PROVIDER1 local-e164 100 remote-e164 0312345678

route call dest-interface BRI0 retry 5 10 10 encapsulation ppp

bind subscriber SUB_PROVIDER1 use profile ppp default

outbound 2 PROVIDER2 local-e164 100 remote-e164 0998887766

route call dest-interface BRI0 retry 5

encapsulation ppp

bind subscriber SUB_PROVIDER2 use profile ppp default

Dial-up

Dial-up is one of the modules you have to configure in order to use the PPP dial-up over ISDN feature. Also consider the check-connectivitycommand (page 338) on the IP interface and the interface dialer mode (page 331) in context cs.

Dial-up brings up an IP interface even if the link is not established (spoofing). On some trigger conditions the spoofer gives the signal to dial or to drop the connection to dialer that is bound to the IP interface. There are three different trigger conditions available.

Dial-up on demand

Dial when the first packet is sent out that interface and drop after a certain time where no packet is routed through that interface.

Mode: context ip/interface

Step

Command

Purpose

 

 

 

1

[name] (if-ip) [interface]#[no] dial-up on-

Configure dial-up on demand. Idle timeout

 

demand [idle timeout <seconds>]

specifies the idle time in seconds before drop-

 

[queue-limit <number>]

ping connection (Default 300). Queue-limit

 

 

specifies the max. number of packets to

 

 

queue while the link is down (Default 4).

 

 

 

PPP Dial-up over ISDN

337

Page 337
Image 337
Patton electronic SmartNode 4110 Series manual Dial-up on demand