SmartWare Software Configuration Guide

14 • Serial port configuration

 

 

Before using the serial interface the hardware port protocol has to be specified. There are two command options available to select the suitable hardware port protocol:

v35 for V.35 protocol to be used

x21 for X.21 protocol to be used

Mode: Administrator execution

Step

Command

Purpose

 

 

 

1

node(cfg)#port serial slot port

Selects the serial interface on slot and port

 

 

 

2

node(prt-ser)[slot/port]#hardware-port {v35 x21}

Sets the hardware port protocol

 

 

 

3

node(prt-ser)[slot/port]#show port serial

Displays the serial interface configuration

 

 

 

Example: Configuring the hardware port protocol

The following example enables X.21 as hardware port protocol for the serial interface on slot 0 and port 0. Check that Hardware Port is set to X.21 in the command output of show port serial.

node(cfg)#port serial 0 0 node(prt-ser)[0/0]#hardware-port x21 node(prt-ser)[0/0]#show port serial

Serial Interface Configuration

------------------------------

Port

:

serial 0 0 0

State

:

CLOSED

Hardware Port

:

X.21

Transmit Edge

:

normal

Port Type

:

DTE

CRC Type

:

CRC-16

Max Frame Length:

2048

Recv Threshold

:

1

Encapsulation

:

framerelay

Configuring the active clock edge

Depending on the system configurations—i.e. when using long cables, with certain modem types or data rates—synchronization problems may occur on the serial port. In these cases, it may be necessary to configure the clock edge on which data is transmitted.

This procedure describes how to set the active clock edge of the serial interface

Mode: Port serial

Step

Command

Purpose

 

 

 

1

node(prt-ser)[slot/port]# transmit-data-

Configures the serial interface to transmit on the

 

on-edge positive

positive edge of the clock (normal, default).

 

 

 

2

node(prt-ser)[slot/port]# transmit-data-

Configures the serial interface to transmit on the

 

on-edge negative

negative edge of the clock (inverted).

 

 

 

Serial port configuration task list