SmartWare Software Configuration Guide

16 • PRI port configuration

 

 

Configuring PRI LOS threshold (E1T1 only)

This command takes effect only if the PRI port is configured for long-haulapplications. It specifies the sensi- tivity for Loss Of Signal threshold. A signal suffers more attenuation over long distances than over short dis- tances. Therefore the LOS-Threshold must be set higher for longer transmission distances. This command has a default value of -46dB what should be enough for distances up to 1600 m/5250 ft.

Mode: port e1t1 <slot> <port>

Step

Command

Purpose

 

 

 

1

[ name] (prt-e1t1)[slot/port]#los-thresh-

Specifies Loss Of Signal Threshold

 

old {-4dB -6dB -8dB-46dB -

Restriction: Only available for e1t1 ports

 

48dB}

Default: -46dB

 

 

 

Configuring PRI Loopback detection (E1T1 only)

In T1 mode the E1T1 PRI port has the capability for auto detection of inband sent loop back codes. Once a loopback-up code is detected, the module automatically enables the proper loopback function and disables it a soon as the corresponding loopback-down code appears. This feature is used by carrier equipment for testing the line to the customer. It sends the loopback-up code to the customer device, then subsequently starts, for example, a Pseudo Random Bit Sequence (PRBS) to determinate the quality of the connection.

Depending on the configured T1 framing, the right loopback code detection mode will be enabled as soon as the command loop-backauto-detectionwill be executed. For framing type uses a different loop- back code detection mechanism:

ESF: The loopback codes are transmitted via the 4kBit/s EOC-Channel, that is part of the 8kBit/s F-Bit Channel. The following codes are supported:

Command

Binary Code

 

 

Line Loopback Activate

0 000111 0

 

 

Line Loopback Deactivate

0 011100 0

 

 

Payload Loopback Acti-

0 001010 0

vate

 

 

 

Payload Loopback Deacti-

0 011001 0

vate

 

 

 

Universal Loopback Deac-

0 010010 0

tivate

 

 

 

Loopback Retention

0 010101 0

 

 

SF and Unframed: An inband loop code pattern is sent for at least 5 seconds in all 24 timeslots. The follow- ing codes are supported:

Command

Binary Repetition Code

 

 

Line Loopback Activate

00001

 

 

Line Loopback Deactivate

001

 

 

PRI port configuration task list

196

Page 196
Image 196