Patton electronic SmartNode 4110 Series Nodeq931slot/port#signalling-rule, Etsi, Pss1old, Range

Models: SmartNode 4110 Series

1 664
Download 664 pages 15.88 Kb
Page 221
Image 221

SmartWare Software Configuration Guide19 • ISDN configuration

Step

Command

Purpose

 

 

 

2

node(q931)[slot/port]#signalling-rule

Specify channel numbering (Default: etsi)

 

etsi

Some older Q-SIG variants make use of a

 

or

 

channel numbering scheme that differs from

 

node(q931)[slot/port]#signalling-rule

the standard ETSI method. In most cases the

 

pss1old

ETSI numbering applies. Unless the connected

 

or

ISDN devices and configured protocols

 

node(q931)[slot/port]#no signalling-rule

require a different scheme, make sure the

 

 

numbering is set to ETSI.

3

node(q931)[slot/port]#uni-side net

Specify the UNI side of the interface.

 

or

If not defined on layer2 (q921 mode) this set-

 

node(q931)[slot/port]#uni-side user

ting also specifies the UNI side setting for

 

 

layer2.

 

 

The layer 2 settings also apply to Q.SIG

 

 

(PSS1) interfaces.

 

 

Make sure that the device connected to a

 

 

SmartNode ISDN port is operating the oppo-

 

 

site side of the configured uni-side.

 

 

 

4

node(q931)[slot/port]#max-calls number-

Limits the total number of concurrent calls

 

of-calls

on the port.

 

or

The no form of the command restores the

 

node(q931)[slot/port]#no max-calls

default settings.

 

 

Note if the channel-range and

 

 

max-calls command are

 

 

used simultaneously, the

 

 

lower number of chan-

 

 

nels is the limiting

 

 

parameter.

 

 

 

5

node(prt-pstn)[slot/port]#channel-range

Specify B-channel range to be used on a PRI

 

min max

port (Default: E1: 0-31, T1: 0-23)

 

or

Limits the time-slots to be used for calls to the

 

node(prt-pstn)[slot/port]#no channel-

range between min and max. This is in some

 

range

cases required for interoperability with ISDN

 

 

services that impose the same limitations.

 

 

Call slots outside the defined range are

 

 

rejected (busy line). If no range is defined

 

 

(Default) all 30 (T1: 23) time-slots are avail-

 

 

able for use.

 

 

The no form of the command restores the

 

 

default settings.

ISDN configuration task list

221

Page 221
Image 221
Patton electronic SmartNode 4110 Series Nodeq931slot/port#signalling-rule, Etsi, Pss1old, Nodeq931slot/port#uni-side net