Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards

Optical Cards

D.4.4.10 Alarm Behavior Tab

 

 

The Alarm Behavior tab allows you to view and update OC192/STM64 XFR-based card alarm profile

 

 

information.

Table D-114

Field Descriptions for the Alarm Behavior Tab

 

 

 

 

Field

 

 

Description

 

 

 

 

Alarm Profile

 

 

Displays the alarm profile that has been configured for the card.

 

 

 

Suppress Alarms

 

If checked, indicates that all alarms are suppressed for the card.

 

 

 

 

Port Number

 

 

Displays the card port number.

 

 

 

 

Alarm Profile

 

 

Choose an alarm profile for the port from the drop-down list. Values are Default, Inherited, or a

 

 

 

customized alarm profile.

 

 

 

Suppress Alarms

 

If checked, all alarms are suppressed for the port.

 

 

 

 

Alarm Profile

 

 

Choose an alarm profile for all ports.

 

 

 

Force to All Ports

 

When clicked, forces all the ports to the selected alarm profile.

 

 

 

 

D.4.4.11 Transceiver Tab

The Transceiver tab allows you to view and update OC192/STM64 XFR-based card transceiver information.

Table D-115

Field Descriptions for the Transceiver Tab

 

 

 

Field

 

Description

 

 

 

Port No.

 

The port number.

 

 

Non-normalized LBC (mA)

The actual operating value of laser bias current (in mA) for the specified card port.

 

 

Non-normalized OPT (dBm)

The actual operating value of optical power transmitted (in dBm) for the specified card port.

 

 

Non-normalized OPR (dBm)

The actual operating value of optical power received (in dBm) for the specified card port.

 

 

 

D.4.4.12 Auto Laser Shutdown Tab

 

 

The Auto Laser Shutdown tab allows you to view and update OC192/STM64 XFR-based card ALS

 

 

parameters.

Table D-116

Field Descriptions for the Auto Laser Shutdown Tab

 

 

 

 

Field

 

 

Description

 

 

 

 

Port No.

 

 

Displays the port number.

 

 

 

 

ALS Mode

 

 

Displays the ALS mode (Disabled, Auto Restart, Manual Restart, or Manual Restart for Test).

 

 

 

Rec. Pulse Dur. (sec)

 

Allows you to set the received laser pulse duration, in seconds. The range is 2.0 to 100.0 seconds.

 

 

 

Rec. Pulse Int. (sec)

 

Allows you to set the received laser pulse interval, in seconds. The range is 60 to 300 seconds.

 

 

 

 

 

 

Cisco Transport Manager Release 7.2 User Guide

 

 

 

 

 

 

 

78-17630-01

 

 

D-111

 

 

 

 

 

Page 111
Image 111
Cisco Systems 78-17630-01 appendix Alarm Behavior Tab, 111