D-251
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards
D.5.11.4 Current Tab
The Current tab allows you to assign performance monitoring thresholds for the receive transponder
Laser 1 current levels.
D.5.11.5 Power Tab
ThePower tab allows you to assign performance monitoring thresholds for the receive transponder Laser
1 power levels.
D.5.11.6 Input Power Tab
TheInput Power tab allows you to assign performance monitoring thresholds for the power coming into
the receive transponder.
Background Block Errors Sets the high threshold for the number of B1 background block errors (BBE) and the alarm
severitylevel. An errored block is a block in which one or more bits are in error. A background
block error is an errored block that does not occur as part of a severely errored second.
Unavailable Seconds Setsthe highthreshold forthe number of B1 unavailable seconds(UAS) and thealarm severity
level. The detection of 10 consecutive SES begins a period of UAS. The 10 SES detected are
part of the UAS. The ES and SES counters decrement by 10 seconds and the UAS counter
increments by an equivalent number of seconds. A new period of available time begins at the
onset of 10 consecutive non-SES events.
TableD-310 Field Descriptions for the Quality of Service Tab (continued)
Field Description
TableD-311 Field Descriptions for the Current Tab
Field Description
Laser 1 Current
Value When the Update button is clicked, displays the Laser 1 current of the receive transponder.
Degrade Sets the degrade threshold for the Laser 1 current (in mA) and the alarm severity level.
Fail Sets the failure threshold for the Laser 1 current (in mA) and the alarm severity level.
TableD-312 Field Descriptions for the Power Tab
Field Description
Laser 1 Power
Value When the Update button is clicked, displays the current power of Laser 1.
Low Sets the low threshold for the Laser 1 power (in mW) and the alarm severity level.
High Sets the high threshold for the Laser 1 power (in mA) and the alarm severity level.