D-176
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards
Optical Cards
Note See Table1-20 on page 1-44 for descriptions of actions that can be performed using the buttons at the
bottom of the window.
D.4.17 Slot Properties—STM-16 (ONS 15454 SDH)
The Slot Properties pane displays information about the Cisco ONS 15454 SDH slot that is selected in
theNE Explorer tree. Use this properties pane to change the module performance monitoring thresholds.
The OC48 IR/STM16 SH AS 1310 card provides one intermediate-range, ITU-T G.707, ITU-T
G.957-compliant,SDH STM-16 port per card. The interface operates at 2.488 Gbps over a single-mode
fiberspan. The card supports concatenated or nonconcatenated payloads at STM-1, STM-4, or STM-16
signal levels on a per-VC-4 basis.
For the STM-16 module, the Slot Properties pane displays the following tabs: Module View,
Identification, Line, VC-4, Loopback, Protection, Alarm Behavior, Auto Laser Shutdown, and J1 Path
Trace.

D.4.17.1 Module View Tab

The Module View tab displays a graphic of the STM-16 that is installed in the slot. The number of
critical,major, minor, and warning alarms for the module is displayed under Alarm Status. (Alarms are
also displayed when you movethe mouse pointer over the graphic.) The Suppress Alarms check box is
read-onlyand indicates whether all alarms are suppressed for the card and its port(s). Right-clicking the
graphic opens a shortcut menu that you can use to reset, delete, or change the card.

D.4.17.2 Identification Tab

The Identification tab allows you to view and update STM-16 identification information.
TableD-193 Field Descriptions for the Identification Tab
Field Description
Equipment Type Displays the equipment type the slot is provisioned for.
Actual Equipment Type Displays the actual card that is installed in the slot.
HW Part Number Displays the card part number that is printed on the top of the card.
Hardware Revision Displays the hardware revision number.
Serial Number Displays the card serial number that is unique to each card.
CLEI Code Displays the CLEI code.
Firmware Version Displays the revision number of the software used by the ASIC chip installed on the card.
Product ID Displays aproduct ID stringof 63 charactersmaximum. Ifthe card doesnot support theproduct
ID, the field shows N/A.
Version ID Displays a version ID string in the format “V99_.” The version ID always begins with a V and
ends with a space. If the card does not support the version ID, the field shows N/A.
Equipment State Displays the equipment state of the card.
Alarm Profile Setsthe alarm profilefor theport. Check theSuppress Alarms check box to suppress all alarms
for this card and its port(s).