D-267
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards
D.5.16 Slot Properties—WCM-10G-Nxx
The Slot Properties pane displays information about the module that is installed in the slot selected in
theNE Explorer tree. Use this properties pane to set performance monitoring thresholds for the module.
Wavelength converter modules (WCMs) are used at terminal (transmit direction) and optical add/drop
multiplexing (OADM) sites to retime, reshape, and regenerate SONET and SDH signals.
A block diagram is shown in the following figure.
FigureD-21 Cisco ONS 15800 or ONS 15801 Wavelength Converter Module–10 Gbps–Normal
For the Wavelength Converter Module–10 Gbps–Normal (WCM-10G-Nxx), the Slot Properties pane
displaysthe following tabs: Module View,Identification, Temperature, Current, Power,Input Power, and
Output Power.

D.5.16.1 Module View Tab

The Module View tab displays a graphic of the transponder that is installed in the slot. The number of
critical,major, minor, and warning alarms for the module is displayed under Alarm Status. (Moving the
mouse pointer over the graphic also displays the alarm counts.) The module status is displayed under
Operational State. Right-clicking the graphic opens a shortcut menu that you can use to display the
module in the Alarm Browser, in the Equipment Inventory Table, or in the LEM PM Table.

D.5.16.2 Identification Tab

The Identification tab allows you to view and update module identification information.
TableD-341 Field Descriptions for the Identification Tab
Field Description
NE ID Displaysthe user-definedname ofthe NE wherethe wavelengthconverter module is installed.
Description Displays information that a user has entered (if any) to describe the NE.
NE Model Identifies the model of the selected NE (ONS 15800 or ONS 15801) where the wavelength
converter module is installed.
Rack ID Displays the identification number of the rack where the subrack containing the wavelength
converter module is installed.
Subrack ID Displays the identificationnumber of the subrackcontaining the wavelength convertermodule.
Slot ID Displays the identification number of the slot containing the wavelength converter module.
Software Version Displays the version of the software.
BIOS Version Displays the version number of the BIOS.
Board Serial Number Displays the serial number of the board.