AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards
D.4.1.1 Module View Tab
TheModule View tab displays a graphic of the OC12 IR/STM4 SH 1310 that is installed in the slot. The
number of critical, major, minor, and warning alarms for the module is displayed under Alarm Status.
(Alarms are also displayed when you move the mouse pointer over the graphic.) The Suppress Alarms
check box is read-only and indicates whether all alarms are suppressed for the card and its port(s).
Right-clicking the graphic opens a shortcut menu that you can use to reset, delete, or change the card.
D.4.1.2 Identification Tab
The Identification tab allows you to view and update OC12 IR/STM4 SH 1310 identification
information.
TableD-83 Field Descriptions for the Identification Tab
Field Description
Equipment Type Displays the equipment type that the slot is provisioned for.
Actual Equipment Type Displays the actual card that is installed in the slot.
Hardware Part Number Displays the card part number that is printed on the top of the card.
Hardware Revision Displays the hardware revision number.
Serial Number Displays the card serial number that is unique to each card.
CLEI Code Displays the CLEI code.
Firmware Version Displays the revision number of the software used by the ASIC chip installed on the card.
Product ID Displays a product ID string of 63 characters maximum. If the card does not support the product
ID, the field shows N/A.
Version ID Displays aversion ID stringin the format“V99_.” The versionID always begins with a V and ends
with a space. If the card does not support the version ID, the field shows N/A.
Administration State The port administration state. It can be:
IS—In Service.
IS, AINS—Automatic In Service.
OOS, DSBLD—Out of Service, Disabled.
OOS, MT—Out of Service, Maintenance.