Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards

Transponder Cards

Table D-327

Field Descriptions for the Identification Tab (continued)

 

 

 

Field

 

Description

 

 

 

Slot ID

 

Displays the identification number of the slot containing the transponder.

 

 

Software Version

Displays the version of the software.

 

 

 

BIOS Version

 

Displays the version number of the BIOS.

 

 

Board Serial Number

Displays the serial number of the board.

 

 

 

SCC Number

 

Displays the version of the module serial communication controller (SCC).

 

 

 

Product Option

 

Displays the product option. Displays Not Available if TL1 Agent version is earlier than version

 

 

2.1.

 

 

Hardware Version

Displays the version of the hardware. Displays Not Available if TL1 Agent version is earlier than

 

 

version 2.1.

 

 

 

Line Direction

 

Shows the line direction for the transponder.

 

 

 

State

 

Allows you to place the transponder in one of two states: In Service or Under Maintenance.

 

 

PM Collection Status

Allows you to enable or disable PM collection for the transponder.

 

 

 

D.5.14.3 Temperature Tab

The Temperature tab allows you to assign performance monitoring thresholds for the transponder operating temperature.

Table D-328 Field Descriptions for the Temperature Tab

Field

Description

Laser 1

Value

When the Update button is clicked, displays the current temperature of Laser 1 (in degrees Celsius).

 

 

Low

Sets the operating temperature low threshold, in degrees Celsius, and the alarm severity level.

 

 

High

Sets the operating temperature high threshold, in degrees Celsius, and the alarm severity level.

 

 

D.5.14.4 Quality of Service Tab

The Quality of Service tab allows you to assign thresholds and alarm severities for B1 counters. Click the 15 min radio button to assign thresholds for 15-minute collection increments. Click the 1 day radio button to assign thresholds for 24-hour collection increments.

Table D-329 Field Descriptions for the Quality of Service Tab

Field

Description

B1 Counters

 

Errored Seconds

Sets the high threshold for the number of B1 errored seconds (ES) and the alarm severity

 

 

level. An errored second is a one-second period with one or more error blocks or at least

 

 

one defect.

 

 

 

 

Severely Errored Seconds

Sets the high threshold for the number of B1 severely errored seconds (SES) and the alarm

 

 

severity level. A severely errored second is a one-second period that contains at least 30%

 

 

errored blocks or at least one defect.

 

 

 

 

 

 

 

 

Cisco Transport Manager Release 7.2 User Guide

 

 

 

 

 

 

 

78-17630-01

 

 

D-261

 

 

 

 

 

Page 261
Image 261
Cisco Systems 78-17630-01 appendix Temperature Tab, 261