D-261
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards
D.5.14.3 Temperature Tab
The Temperature tab allows you to assign performance monitoring thresholds for the transponder
operating temperature.
D.5.14.4 Quality of Service Tab
The Quality of Service tab allows you to assign thresholds and alarm severities for B1 counters. Click
the15 min radio button to assign thresholds for 15-minute collection increments. Click the 1 day radio
button to assign thresholds for 24-hour collection increments.
Slot ID Displays the identification number of the slot containing the transponder.
Software Version Displays the version of the software.
BIOS Version Displays the version number of the BIOS.
Board Serial Number Displays the serial number of the board.
SCC Number Displays the version of the module serial communication controller (SCC).
Product Option Displays the product option. Displays Not Available if TL1 Agent version is earlier than version
2.1.
Hardware Version Displays the versionof thehardware. Displays Not Available if TL1 Agent version is earlierthan
version 2.1.
Line Direction Shows the line direction for the transponder.
State Allows you to place the transponder in one of two states: In Service or Under Maintenance.
PM Collection Status Allows you to enable or disable PM collection for the transponder.
TableD-327 Field Descriptions for the Identification Tab (continued)
Field Description
TableD-328 Field Descriptions for the Temperature Tab
Field Description
Laser 1
Value When the Update button is clicked, displays the current temperature of Laser 1 (in degrees Celsius).
Low Sets the operating temperature low threshold, in degrees Celsius, and the alarm severity level.
High Sets the operating temperature high threshold, in degrees Celsius, and the alarm severity level.
TableD-329 Field Descriptions for the Quality of Service Tab
Field Description
B1 Counters
Errored Seconds Sets the high threshold for the number of B1 errored seconds (ES) andthe alarm severity
level. An errored second is a one-second period with one or more error blocks or at least
one defect.
Severely Errored Seconds Sets thehigh threshold forthe number ofB1 severely erroredseconds (SES) andthe alarm
severitylevel. A severely errored second is a one-second period that contains at least 30%
errored blocks or at least one defect.