Appendix D Slot Property
Optical Cards
Table | Field Descriptions for the Protection Tab | |
|
|
|
Field |
| Description |
|
| |
Protection Groups | Displays a list of available protection groups. | |
|
| |
Protection Group Details | Displays details about the selected protection group. | |
|
|
|
D.4.9.7 Alarm Behavior Tab
|
| The Alarm Behavior tab allows you to view and update OC48 LR 1550 alarm profile information. |
Table | Field Descriptions for the Alarm Behavior Tab | |
|
|
|
Field |
| Description |
|
|
|
Alarm Profile |
| Displays the alarm profile that has been configured for the card. |
|
| |
Suppress Alarms | If checked, indicates that all alarms are suppressed for the card. | |
|
|
|
Port Number |
| Displays the card port number. |
|
|
|
Alarm Profile |
| Choose an alarm profile for the port from the |
|
| customized alarm profile. |
|
| |
Suppress Alarms | If checked, all alarms are suppressed for the port. | |
|
|
|
Alarm Profile |
| Choose an alarm profile for all ports. |
|
| |
Force to All Ports | When clicked, forces all the ports to the selected alarm profile. | |
|
|
|
D.4.9.8 Auto Laser Shutdown Tab
|
| The Auto Laser Shutdown tab allows you to view and update OC48 LR 1550 ALS parameters. | |
Table | Field Descriptions for the Auto Laser Shutdown Tab | ||
|
|
|
|
Field |
|
| Description |
|
|
|
|
Port No. |
|
| Displays the port number. |
|
|
|
|
ALS Mode |
|
| Displays the ALS mode (Disabled, Auto Restart, Manual Restart, or Manual Restart for Test). |
|
|
| |
Rec. Pulse Dur. (sec) |
| Allows you to set the received laser pulse duration, in seconds. The range is 2.0 to 100.0 seconds. | |
|
|
| |
Rec. Pulse Int. (sec) |
| Allows you to set the received laser pulse interval, in seconds. The range is 60 to 300 seconds. | |
|
|
|
|
Status |
|
| Displays the current laser status. Values are Shutdown or Not Shutdown. |
|
|
|
|
Request Restart |
|
| If selected, it allows you to request a laser restart. This parameter is configurable only when the |
|
|
| ALS mode is set to Manual Restart or Manual Restart for Test and when the laser status is Shut |
|
|
| Down. |
|
|
|
|
D.4.9.9 Info Tab
The Info tab allows you to view nominal operating values set during manufacturing for the OC48 LR 1550 module.
| Cisco Transport Manager Release 7.2 User Guide |
|