Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards

Optical Cards

Table D-157

Field Descriptions for the Protection Tab

 

 

 

Field

 

Description

 

 

Protection Groups

Displays a list of available protection groups.

 

 

Protection Group Details

Displays details about the selected protection group.

 

 

 

D.4.9.7 Alarm Behavior Tab

 

 

The Alarm Behavior tab allows you to view and update OC48 LR 1550 alarm profile information.

Table D-158

Field Descriptions for the Alarm Behavior Tab

 

 

 

Field

 

Description

 

 

 

Alarm Profile

 

Displays the alarm profile that has been configured for the card.

 

 

Suppress Alarms

If checked, indicates that all alarms are suppressed for the card.

 

 

 

Port Number

 

Displays the card port number.

 

 

 

Alarm Profile

 

Choose an alarm profile for the port from the drop-down list. Values are Default, Inherited, or a

 

 

customized alarm profile.

 

 

Suppress Alarms

If checked, all alarms are suppressed for the port.

 

 

 

Alarm Profile

 

Choose an alarm profile for all ports.

 

 

Force to All Ports

When clicked, forces all the ports to the selected alarm profile.

 

 

 

D.4.9.8 Auto Laser Shutdown Tab

 

 

The Auto Laser Shutdown tab allows you to view and update OC48 LR 1550 ALS parameters.

Table D-159

Field Descriptions for the Auto Laser Shutdown Tab

 

 

 

 

Field

 

 

Description

 

 

 

 

Port No.

 

 

Displays the port number.

 

 

 

 

ALS Mode

 

 

Displays the ALS mode (Disabled, Auto Restart, Manual Restart, or Manual Restart for Test).

 

 

 

Rec. Pulse Dur. (sec)

 

Allows you to set the received laser pulse duration, in seconds. The range is 2.0 to 100.0 seconds.

 

 

 

Rec. Pulse Int. (sec)

 

Allows you to set the received laser pulse interval, in seconds. The range is 60 to 300 seconds.

 

 

 

 

Status

 

 

Displays the current laser status. Values are Shutdown or Not Shutdown.

 

 

 

 

Request Restart

 

 

If selected, it allows you to request a laser restart. This parameter is configurable only when the

 

 

 

ALS mode is set to Manual Restart or Manual Restart for Test and when the laser status is Shut

 

 

 

Down.

 

 

 

 

D.4.9.9 Info Tab

The Info tab allows you to view nominal operating values set during manufacturing for the OC48 LR 1550 module.

 