Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards

Optical Cards

D.4.19.2 Identification Tab

The Identification tab allows you to view and update STM-4 IR/STM4 SH 1310 identification information.

Table D-209

Field Descriptions for the Identification Tab

 

 

 

Field

 

Description

 

 

 

Equipment Type

 

Displays the equipment type the slot is provisioned for.

 

 

Actual Equipment Type

Displays the actual card that is installed in the slot.

 

 

 

Part Number

 

Displays the card part number that is printed on the top of the card.

 

 

Hardware Revision

Displays the hardware revision number of the card.

 

 

 

Serial Number

 

Displays the card serial number that is unique to each card.

 

 

 

CLEI Code

 

Displays the CLEI code.

 

 

Firmware Version

Displays the revision number of the software used by the ASIC chip installed on the card.

 

 

 

Equipment State

 

Displays the equipment state of the card.

 

 

 

Alarm Profile

 

Sets the alarm profile for the port. Check the Suppress Alarms check box to suppress all alarms

 

 

for this card and its port(s).

 

 

 

D.4.19.3 Line Tab

 

The Line tab allows you to view and update STM-4 IR/STM4 SH 1310 line performance monitoring

 

information.

Table D-210

Field Descriptions for the Line Tab

 

 

 

Field

 

Description

 

 

 

Line Config

 

 

 

 

 

Port Number

 

Displays the optical port number.

 

 

 

Port Name

 

Allows you to enter an optical port name.

 

 

 

SD BER

 

Sets the signal degrade bit error rate.

 

 

 

SF BER

 

Sets the signal fail bit error rate.

 

 

 

Type

 

Defines the port.

 

 

 

PJVC-4 Mon#

 

Sets the VC that will be used for pointer justification. If set to 0, no VC is monitored. Only one

 

 

VC can be monitored on each STM port.

 

 

 

ProvidesSync

 

If checked, the card is provisioned as an NE timing reference.

 

 

 

EnableSyncMsg

 

Enables synchronization status messages (S1 byte), which allow the node to choose the best

 

 

timing source.

 

 

 

Send DoNotUse

 

When checked, sends a DNS (do not use) message on the S1 byte.

 

 

 

Admin State

 

Select the designation that drives whether an entity is in service or out of service. The Admin

 

 

state is the driver for the Service state.

 

 

 

 

Cisco Transport Manager Release 7.2 User Guide

D-190

78-17630-01

Page 190
Image 190
Cisco Systems 78-17630-01 appendix Identification Tab, 190