D-64
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards
Multirate Cards
D.3.2.11 Transceiver Tab
The Transceiver tab allows you to view and update MRC-12 transceiver information.
D.3.2.12 Auto Laser Shutdown Tab
The Auto Laser Shutdown tab allows you to view and update MRC-12 ALS parameters.
D.3.2.13 Section Trace Subtab
The Section Trace subtab allows you to change the section trace settings for the MRC-12 card.
TableD-77 Field Descriptions for the Alarm Behavior Tab
Field Description
Port Number Displays the card port number.
Alarm Profile Choose an alarm profile for the port from the drop-down list. Values are Default, Inherited, or a
customized alarm profile.
Suppress Alarms If checked, all alarms are suppressed for the port.
Alarm Profile Choose an alarm profile for all ports.
Force to All Ports When clicked, forces all the ports to the selected alarm profile.
TableD-78 Field Descriptions for the Transceiver Tab
Field Description
Port No. PIM number, PPM number, Port number.
Non-normalized LBC (mA) The actual operating value of laser bias current (in mA) for the specified card port.
Non-normalized OPT (dBm) Theactual operatingvalue ofopticalpower transmitted(in dBm)for the specified card port.
Non-normalized OPR (dBm) The actual operating value of optical power received (in dBm) for the specified card port.
TableD-79 Field Descriptions for the Auto Laser Shutdown Tab
Field Description
Port No. Displays the port number.
ALS Mode Displays the ALS mode (Disabled, Auto Restart, Manual Restart, or Manual Restart for Test).
Rec. Pulse Dur. (sec) Allows you to set the received laser pulse duration, in seconds. The range is 2.0 to 100.0 seconds.
Rec. Pulse Int. (sec) Allows you to set the received laser pulse interval, in seconds. The range is 60 to 300 seconds.
Status Displays the current laser status. Values are Shutdown or Not Shutdown.
Request Restart If selected,it allows youto request alaser restart. This parameter is configurableonly when theALS
mode is set to Manual Restart or Manual Restart for Test and when the laser status is Shut Down.