Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards

Optical Cards

Table D-109

Field Descriptions for the Line Tab (continued)

 

 

 

Field

 

Description

 

 

 

Admin SSM

 

If the node does not receive an SSM signal, it defaults to STU (synchronization traceability

 

 

unknown). Admin SSM allows you to override the STU value with one of the following:

 

 

PRS—Primary reference source (Stratum 1)

 

 

STS2—Stratum 2

 

 

TNC—Transit node clock

 

 

STS3E—Stratum 3E

 

 

STS3—Stratum 3

 

 

SMC—SONET minimum clock

 

 

ST4—Stratum 4

 

 

 

Send <FF>

 

When checked, sends a special do not use (DUS) (0xff) message on the S1 byte.

DoNotUse

 

 

 

 

 

 

PJ VC-4 Mon#

 

Sets the VC that will be used for pointer justification. If set to 0, no VC is monitored. Only one VC

 

 

can be monitored on each STM port.

 

 

 

 

 

 

Cisco Transport Manager Release 7.2 User Guide

 

 

 

 

 

 

 

78-17630-01

 

 

D-103

 

 

 

 

 

Page 103
Image 103