D-276
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards
Transponder Cards
D.5.18.3 Temperature Tab
The Temperature tab allows you to assign performance monitoring thresholds for the wavelength
converter module laser temperature.
D.5.18.4 Quality of Service Tab
TheQuality of Service tab allows you to assign thresholds and alarm severities for B1 and FEC counters.
Clickthe 15 min radio button to assign thresholds for 15-minute collection increments. Click the 1 day
radio button to assign thresholds for 24-hour collection increments.
SCC Number Displays the version of the module serial communication controller (SCC).
Product Option Displaysthe productoption. Displays“Not Available”if the TL1 Agent version is earlier than
version 2.1.
Hardware Version Displays the version of the hardware. Displays “Not Available” if the TL1 Agent version is
earlier than version 2.1.
Line Direction Shows the line direction for the wavelength converter module.
State Allowsyou to place the wavelength converter module in one of two states: In Service or Under
Maintenance.
PM Collection Status Allows you to enable or disable PM data collection for the wavelength converter module.
TableD-355 Field Descriptions for the Identification Tab (continued)
Field Description
TableD-356 Field Descriptions for the Temperature Tab
Field Description
Laser 1 Temperature
Value When the Update button is clicked, displays the current temperature of Laser 1.
Low Sets the low temperature threshold for Laser 1 (in degrees Celsius) and the alarm severity level.
High Sets the high temperature threshold for Laser 1 (in degrees Celsius) and the alarm severity level.
TableD-357 Field Descriptions for the Quality of Service Tab
Field Description
B1 Counters
Errored Seconds Sets the high threshold for the number of B1 errored seconds (ES) and the alarm severity
level.An errored second is a one-second period with one or more error blocks or at least one
defect.
Severely Errored Seconds Sets the high threshold for the number of B1 severely errored seconds (SES) and the alarm
severity level. A severely errored second is a one-second period that contains at least 30
percent of errored blocks or at least one defect.
Background Block Errors Setsthe high threshold for the number of B1 background block errors (BBE) and the alarm
severity level. An errored block is a block in which one or more bits are in error. A
background block error is an errored block that does not occur as part of a severely errored