Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards

Transponder Cards

Table D-355

Field Descriptions for the Identification Tab (continued)

 

 

 

Field

 

Description

 

 

 

SCC Number

 

Displays the version of the module serial communication controller (SCC).

 

 

 

Product Option

 

Displays the product option. Displays “Not Available” if the TL1 Agent version is earlier than

 

 

version 2.1.

 

 

Hardware Version

Displays the version of the hardware. Displays “Not Available” if the TL1 Agent version is

 

 

earlier than version 2.1.

 

 

 

Line Direction

 

Shows the line direction for the wavelength converter module.

 

 

 

State

 

Allows you to place the wavelength converter module in one of two states: In Service or Under

 

 

Maintenance.

 

 

PM Collection Status

Allows you to enable or disable PM data collection for the wavelength converter module.

 

 

 

D.5.18.3 Temperature Tab

The Temperature tab allows you to assign performance monitoring thresholds for the wavelength converter module laser temperature.

Table D-356 Field Descriptions for the Temperature Tab

Field

Description

Laser 1 Temperature

Value

When the Update button is clicked, displays the current temperature of Laser 1.

 

 

Low

Sets the low temperature threshold for Laser 1 (in degrees Celsius) and the alarm severity level.

 

 

High

Sets the high temperature threshold for Laser 1 (in degrees Celsius) and the alarm severity level.

 

 

D.5.18.4 Quality of Service Tab

The Quality of Service tab allows you to assign thresholds and alarm severities for B1 and FEC counters. Click the 15 min radio button to assign thresholds for 15-minute collection increments. Click the 1 day radio button to assign thresholds for 24-hour collection increments.

Table D-357 Field Descriptions for the Quality of Service Tab

 

Field

Description

 

 

 

 

 

B1 Counters

 

 

 

 

 

 

Errored Seconds

Sets the high threshold for the number of B1 errored seconds (ES) and the alarm severity

 

 

 

 

level. An errored second is a one-second period with one or more error blocks or at least one

 

 

 

 

defect.

 

 

 

 

Severely Errored Seconds

Sets the high threshold for the number of B1 severely errored seconds (SES) and the alarm

 

 

 

 

severity level. A severely errored second is a one-second period that contains at least 30

 

 

 

 

percent of errored blocks or at least one defect.

 

 

 

 

Background Block Errors

Sets the high threshold for the number of B1 background block errors (BBE) and the alarm

 

 

 

 

severity level. An errored block is a block in which one or more bits are in error. A

 

 

 

 

background block error is an errored block that does not occur as part of a severely errored

 

 

 

 

second.

 

 

 

 

 

 

 

 

Cisco Transport Manager Release 7.2 User Guide

 

 

 

 

D-276

 

 

78-17630-01

 

 

 

 

 

Page 276
Image 276
Cisco Systems 78-17630-01 appendix Temperature Tab, 276