Appendix D Slot Property
Transponder Cards
D.5.1.3.1 Temperature Subtab
The Temperature subtab allows you to assign
Table
Field
Description
Laser 1
Value | When the Update button is clicked, displays the current temperature of Laser 1 (in degrees Celsius). |
|
|
Low | Sets the operating temperature low threshold, in degrees Celsius, and the alarm severity level. |
|
|
High | Sets the operating temperature high threshold, in degrees Celsius, and the alarm severity level. |
|
|
D.5.1.3.2 Current Subtab
The Current subtab allows you to assign thresholds and alarm severities for the transponder laser current levels.
Table
Field
Description
Laser 1
Value | When the Update button is clicked, displays the current value of the Laser 1 current (in mA). |
|
|
Degrade | Sets the degrade threshold for the Laser 1 current, in mA, and the alarm severity level. |
|
|
Fail | Sets the failure threshold for the Laser 1 current, in mA, and the alarm severity level. |
|
|
D.5.1.3.3 Power Subtab
The Power subtab allows you to assign thresholds and alarm severities for the transponder laser power levels.
Table
Field
Description
Laser 1
Value | When the Update button is clicked, displays the current power of Laser 1 (in mW). |
|
|
Low | Sets the low threshold for the Laser 1 power, in mW, and the alarm severity level. |
|
|
High | Sets the high threshold for the Laser 1 power, in mW, and the alarm severity level. |
|
|
D.5.1.3.4 Input Power Subtab
The Input Power subtab allows you to assign thresholds and alarm severities for the power coming into the transponder lasers.
|