D-281
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards
D.5.19.4 Quality of Service Tab
The Quality of Service tab allows you to assign high alarm thresholds and severities for B1 counters.
Clickthe 15 min radio button to assign thresholds for 15-minute collection increments. Click the 1 day
radio button to assign thresholds for 24-hour collection increments.
D.5.19.5 Current Tab
The Current tab allows you to assign alarm thresholds and severities for the wavelength converter
module laser current levels.
TableD-364 Field Descriptions for the Temperature Tab
Field Description
Laser 1 Temperature
Value When the Update button is clicked, displays the current temperature of Laser 1.
Low Sets the low temperature threshold for Laser 1 (in degrees Celsius) and the alarm severity level.
High Sets the high temperature threshold for Laser 1 (in degrees Celsius) and the alarm severity level.
TableD-365 Field Descriptions for the Quality of Service Tab
Field Description
B1 Counters
Errored Seconds Setsthe highthresholdfor thenumber of B1errored seconds(ES) and the alarm severity level.
Anerrored second is a one-second period with one or more error blocks or at least one defect.
Severely Errored Seconds Sets the high threshold for the number of B1 severely errored seconds (SES) and the alarm
severity level. A severely errored second is a one-second period that contains at least 30
percent of errored blocks or at least one defect.
Background Block Errors Sets the high threshold for the number of B1 background block errors (BBE) and the alarm
severitylevel. An errored block is a block in which one or more bits are in error. A background
block error is an errored block that does not occur as part of a severely errored second.
Unavailable Seconds Setsthe high thresholdfor the number ofB1 unavailable seconds(UAS) and thealarm severity
level.The detection of 10 consecutive SES begins a period of UAS. The 10 SES detected are
part of the UAS. The ES and SES counters decrement by 10 seconds and the UAS counter
increments by an equivalentnumber of seconds. A new period of available time begins at the
onset of 10 consecutive non-SES events.
TableD-366 Field Descriptions for the
C
urrent Tab
Field Description
Laser 1
Value When the Update button is clicked, displays the current value of the Laser 1 current (in mA).
Degrade Sets the degrade threshold for the Laser 1 current (in mA) and the alarm severity level.
Fail Sets the failure threshold for the Laser 1 current (in mA) and the alarm severity level.