Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards

Transponder Cards

Table D-364 Field Descriptions for the Temperature Tab

Field

Description

Laser 1 Temperature

Value

When the Update button is clicked, displays the current temperature of Laser 1.

 

 

Low

Sets the low temperature threshold for Laser 1 (in degrees Celsius) and the alarm severity level.

 

 

High

Sets the high temperature threshold for Laser 1 (in degrees Celsius) and the alarm severity level.

 

 

D.5.19.4 Quality of Service Tab

The Quality of Service tab allows you to assign high alarm thresholds and severities for B1 counters. Click the 15 min radio button to assign thresholds for 15-minute collection increments. Click the 1 day radio button to assign thresholds for 24-hour collection increments.

Table D-365 Field Descriptions for the Quality of Service Tab

Field

Description

 

 

B1 Counters

 

 

 

Errored Seconds

Sets the high threshold for the number of B1 errored seconds (ES) and the alarm severity level.

 

An errored second is a one-second period with one or more error blocks or at least one defect.

 

 

Severely Errored Seconds

Sets the high threshold for the number of B1 severely errored seconds (SES) and the alarm

 

severity level. A severely errored second is a one-second period that contains at least 30

 

percent of errored blocks or at least one defect.

 

 

Background Block Errors

Sets the high threshold for the number of B1 background block errors (BBE) and the alarm

 

severity level. An errored block is a block in which one or more bits are in error. A background

 

block error is an errored block that does not occur as part of a severely errored second.

 

 

Unavailable Seconds

Sets the high threshold for the number of B1 unavailable seconds (UAS) and the alarm severity

 

level. The detection of 10 consecutive SES begins a period of UAS. The 10 SES detected are

 

part of the UAS. The ES and SES counters decrement by 10 seconds and the UAS counter

 

increments by an equivalent number of seconds. A new period of available time begins at the

 

onset of 10 consecutive non-SES events.

 

 

D.5.19.5 Current Tab

The Current tab allows you to assign alarm thresholds and severities for the wavelength converter module laser current levels.

Table D-366 Field Descriptions for the Current Tab

Field

Description

Laser 1

Value

When the Update button is clicked, displays the current value of the Laser 1 current (in mA).

 

 

Degrade

Sets the degrade threshold for the Laser 1 current (in mA) and the alarm severity level.

 

 

Fail

Sets the failure threshold for the Laser 1 current (in mA) and the alarm severity level.

 

 

 

 