Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards

Optical Cards

Table D-91

Field Descriptions for the Line Tab (continued)

 

 

 

 

 

 

 

Service State

 

Overall availability of the entity. Values are:

 

 

 

 

IS_NR—In Service–Normal.

 

 

 

 

OOS_AU—Out of Service–Autonomous.

 

 

 

 

OOS_MA—Out of Service–Management.

 

 

 

 

OOS_AUMA—Out of Service–Autonomous and Management.

 

 

 

 

In addition, a secondary state provides additional information about the status of the entity. Values for

 

 

 

 

secondary state are:

 

 

 

 

MEA—Mismatch of equipment due to invalid equipment insertion.

 

 

 

 

UEQ—Unequipped. There is nothing in the slot.

 

 

 

 

UAS—Unassigned. The entity does not exist, has not been created, or has been deleted.

 

 

 

 

SWDL—Software download in progress.

 

 

 

 

MT—Maintenance, as per the Admin State change.

 

 

 

 

AINS—Automatic In Service.

 

 

 

 

DSBLD—Traffic is disabled on the entity.

 

 

 

 

LPBK—Port or connection has a loopback on it.

 

 

 

 

FLT—Fault secondary state. When an entity is faulted, an FLT state is raised. Equipment and

 

 

 

 

 

ports in FLT state should be cleared as they transition. Transition states are listed in Table 11-10

 

 

 

 

 

on page 11-15.

 

 

 

 

See Table 11-10 on page 11-15for the Service state/Secondary state possible values.

 

 

 

 

Note If the NE release does not support the Service state, this field shows N/A.

 

 

 

 

 

 

 

Admin SSM

 

If the node does not receive an SSM signal, it defaults to STU (synchronization traceability unknown).

 

 

 

 

Admin SSM allows you to override the STU value with one of the following:

 

 

 

 

PRS—Primary reference source (Stratum 1)

 

 

 

 

STS2—Stratum 2

 

 

 

 

TNC—Transit node clock

 

 

 

 

STS3E—Stratum 3E

 

 

 

 

STS3—Stratum 3

 

 

 

 

SMC—SONET minimum clock

 

 

 

 

ST4—Stratum 4

 

 

 

 

 

 

 

Send <<FF>

 

When checked, sends a do not use (DUS) message on the S1 byte.

 

 

DoNotUse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Line Threshold 15 Minutes

 

 

 

 

 

 

 

 

 

 

 

 

 

Near End

 

 

 

 

 

 

 

 

 

 

 

 

Port Number

 

The optical port number

 

 

 

 

 

 

 

ES-L

 

Errored seconds–line

 

 

 

 

 

 

 

SES-L

 

Severely errored seconds–line

 

 

 

 

 

 

 

CV-L

 

Coding violations–line

 

 

 

 

 

 

 

UAS-L

 

Unavailable seconds–line

 

 

 

 

 

 

 

 

 

 

 

 

 

Cisco Transport Manager Release 7.2 User Guide

 

 

 

 

 

 

 

 

 

 

78-17630-01

 

 

 

 

D-79

 

 

 

 

 

 

 