D-226
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards
Transponder Cards
FigureD-10 Cisco ONS 15800 or ONS 15801 Line Extender Module–10-Gbps–B1 Monitoring
The ONS 15800 or ONS 15801 transponder modules shown on this sheet include:
Line Extender Module–10 Gbps–B1 Monitoring (LEM-10G-Mxx)
Line Extender Module–10 Gbps High Output Power–B1 Monitoring (LEM-10H-Mxx)
For these transponders, the Slot Properties pane displays the following tabs: Module View,
Identification, Temperature, Quality of Service, Current, Power, Input Power, and Output Power.
D.5.4.1 Module View Tab
The Module View tab displays a graphic of the transponder that is installed in the slot. The number of
critical,major, minor, and warning alarms for the module is displayed under Alarm Status. (Moving the
mouse pointer over the graphic also displays the alarm counts.) The module status is displayed under
Operational State. Right-clicking the graphic opens a shortcut menu that you can use to display the
module in the Alarm Browser, in the Equipment Inventory Table, or in the B1 LEM PM Table.
D.5.4.2 Identification Tab
The Identification tab allows you to view and update transponder identification information.
TableD-265 Field Descriptions for the Identification Tab
Field Description
NE ID Displays the user-defined name of the NE where the transponder is installed.
Description Displays information that a user has entered (if any) to describe the NE.
NE Model Identifies the model of the selected NE (ONS 15800 or ONS 15801) where the transponder is
installed.
Rack ID Displays the identification number of the rack where the subrack containing the transponder is
installed.
Subrack ID Displays the identification number of the subrack.
Slot ID Displays the identification number of the slot containing the transponder.
Software Version Displays the version of the software.
BIOS Version Displays the version number of the BIOS.