AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards
Multirate Cards
D.3.1.9 J1 Path Trace Tab
The J1 Path Trace tab allows you to view and update J1 path trace information.
D.3.1.10 Info Tab
The Info tab allows you to view nominal operating values set during manufacturing for the ASAP_4
card.
D.3.1.11 Ether Line Tab
The Ether Line tab allows you to configure Ether line information.
TableD-37 Field Descriptions for the Alarm Behavior Tab
Field Description
Port Number Displays the card port number.
Alarm Profile Choose an alarm profile for the port from the drop-down list. Values are Default, Inherited, or a
customized alarm profile.
Suppress Alarms If checked, all alarms are suppressed for the port.
Alarm Profile Choose an alarm profile for all ports.
Force to All Ports When clicked, forces all the ports to the selected alarm profile.
TableD-38 Field Descriptions for the J1 Path Trace Tab
Field Description
Port Number Displays the port number.
STS Number Displays the STS number.
Expected String Displays the current expected string.
Received String Displays the current received string.
Mode Displays the path trace mode (Off/None, Auto, or Manual).
C2 Represents a machine-generated J1/J2 payload label byte.
TableD-39 Field Descriptions for the Info Tab
Field Description
Extended Manufacturing Information
Attribute Displays the nominal card specification.
Value Displays the value of the attribute.
TableD-40 Field Descriptions for the Ether Line Tab
Field Description
Port Number The port number.
Port Name Allows you to enter a port name.