Appendix D Slot Property
Transponder Cards
Table
Field | Description |
|
|
Background Block Errors | Sets the high threshold for the number of B1 background block errors (BBE) and the alarm |
| severity level. An errored block is a block in which one or more bits are in error. A background |
| block error is an errored block that does not occur as part of a severely errored second. |
|
|
Unavailable Seconds | Sets the high threshold for the number of B1 unavailable seconds (UAS) and the alarm severity |
| level. The detection of 10 consecutive SES begins a period of UAS. The 10 SES detected are part |
| of the UAS. The ES and SES counters decrement by 10 seconds and the UAS counter increments |
| by an equivalent number of seconds. A new period of available time begins at the onset of 10 |
| consecutive |
|
|
D.5.4.5 Current Tab
| The Current tab allows you to assign performance monitoring thresholds for the transponder laser |
| current levels. |
Table | Field Descriptions for the Current Tab |
|
|
Field | Description |
|
|
Value | When the Update button is clicked, displays the current value of the transponder laser current. |
|
|
Degrade | Sets the degrade threshold for the laser current (in mA) and the alarm severity level. |
|
|
Fail | Sets the failure threshold for the laser current (in mA) and the alarm severity level. |
|
|
D.5.4.6 Power Tab
| The Power tab allows you to assign performance monitoring thresholds for the transponder Laser 1 |
| power levels. |
Table | Field Descriptions for the Power Tab |
|
|
Field | Description |
|
|
Value | When the Update button is clicked, displays the current power of Laser 1. |
|
|
Low | Sets the low threshold for the laser power (in mW) and the alarm severity level. |
|
|
High | Sets the high threshold for the laser power (in mW) and the alarm severity level. |
|
|
D.5.4.7 Input Power Tab
The Input Power tab allows you to assign performance monitoring thresholds for the power coming into the transponder.
Table
| Field |
| Description | |
|
|
|
| |
| Value |
| When the Update button is clicked, displays the current transponder input power. | |
|
|
|
| |
| Fail |
| Sets the fail threshold for the module input power in dBm and the alarm severity level. | |
|
|
|
| |
| Degrade |
| Sets the degrade threshold for the module input power (in dBm) and the alarm severity level. | |
|
|
|
| |
|
|