Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards

Transponder Cards

Table D-267 Field Descriptions for the Quality of Service Tab (continued)

Field

Description

 

 

Background Block Errors

Sets the high threshold for the number of B1 background block errors (BBE) and the alarm

 

severity level. An errored block is a block in which one or more bits are in error. A background

 

block error is an errored block that does not occur as part of a severely errored second.

 

 

Unavailable Seconds

Sets the high threshold for the number of B1 unavailable seconds (UAS) and the alarm severity

 

level. The detection of 10 consecutive SES begins a period of UAS. The 10 SES detected are part

 

of the UAS. The ES and SES counters decrement by 10 seconds and the UAS counter increments

 

by an equivalent number of seconds. A new period of available time begins at the onset of 10

 

consecutive non-SES events.

 

 

D.5.4.5 Current Tab

 

The Current tab allows you to assign performance monitoring thresholds for the transponder laser

 

current levels.

Table D-268

Field Descriptions for the Current Tab

 

 

Field

Description

 

 

Value

When the Update button is clicked, displays the current value of the transponder laser current.

 

 

Degrade

Sets the degrade threshold for the laser current (in mA) and the alarm severity level.

 

 

Fail

Sets the failure threshold for the laser current (in mA) and the alarm severity level.

 

 

D.5.4.6 Power Tab

 

The Power tab allows you to assign performance monitoring thresholds for the transponder Laser 1

 

power levels.

Table D-269

Field Descriptions for the Power Tab

 

 

Field

Description

 

 

Value

When the Update button is clicked, displays the current power of Laser 1.

 

 

Low

Sets the low threshold for the laser power (in mW) and the alarm severity level.

 

 

High

Sets the high threshold for the laser power (in mW) and the alarm severity level.

 

 

D.5.4.7 Input Power Tab

The Input Power tab allows you to assign performance monitoring thresholds for the power coming into the transponder.

Table D-270 Field Descriptions for the Input Power Tab

 

Field

 

Description

 

 

 

 

 

Value

 

When the Update button is clicked, displays the current transponder input power.

 

 

 

 

 

Fail

 

Sets the fail threshold for the module input power in dBm and the alarm severity level.

 

 

 

 

 

Degrade

 

Sets the degrade threshold for the module input power (in dBm) and the alarm severity level.

 

 

 

 

 

 

 

Cisco Transport Manager Release 7.2 User Guide

 

 

 

 

D-228

78-17630-01

 

 

 

Page 228