Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards

Optical Cards

Table D-235

Field Descriptions for the Loopback Tab

 

 

 

Field

 

Description

 

 

 

Port Number

 

Displays the port number.

 

 

 

Admin State

 

Shows the administrative state of the port: In Service (IS), Out of Service–Disabled (OOS, DSBLD), or

 

 

Out of Service–Maintenance (OOS_MT).

 

 

 

Loopback Type

 

Allows you to configure a port to terminal loopback (Inward) or Facility (Line), or clear the current

 

 

loopback (None).

 

 

Note The line state must be OOS_MT before you can configure the loopback type.

 

 

 

Service State

 

Overall availability of the entity. Values are:

 

 

IS_NR—In Service–Normal.

 

 

OOS_AU—Out of Service–Autonomous.

 

 

OOS_MA—Out of Service–Management.

 

 

OOS_AUMA—Out of Service–Autonomous and Management.

 

 

In addition, a secondary state provides additional information about the status of the entity. Values for

 

 

secondary state are:

 

 

MEA—Mismatch of equipment due to invalid equipment insertion.

 

 

UEQ—Unequipped. There is nothing in the slot.

 

 

UAS—Unassigned. The entity does not exist, has not been created, or has been deleted.

 

 

SWDL—Software download in progress.

 

 

MT—Maintenance, as per the Admin State change.

 

 

AINS—Automatic In Service.

 

 

DSBLD—Traffic is disabled on the entity.

 

 

LPBK—Port or connection has a loopback on it.

 

 

FLT—Fault secondary state. When an entity is faulted, an FLT state is raised. Equipment and ports

 

 

 

in FLT state should be cleared as they transition. Transition states are listed in Table 11-10 on page

 

 

 

11-15.

 

 

See Table 11-10 on page 11-15for the Service state/Secondary state possible values.

 

 

Note If the NE release does not support the Service state, this field shows N/A.

 

 

 

 

D.4.23.6 Transceiver Tab

The Transceiver tab allows you to view and update STM-64 LR/LH 4 transceiver information.

Table D-236

Field Descriptions for the Transceiver Tab

 

 

 

 

 

 

 

Field

 

Description

 

 

 

 

 

 

 

Port No.

 

Port No. Port number 1–14.

 

 

 

 

 

 

Non-normalized LBC (mA)

The actual operating value of laser bias current (in mA) for the specified card port.

 

 

 

 

 

 

Non-normalized OPT (dBm)

The actual operating value of optical power transmitted (in dBm) for the specified card port.

 

 

 

 

 

 

Non-normalized OPR (dBm)

The actual operating value of optical power received (in dBm) for the specified card port.

 

 

 

 

 

 

 

 

 

 

 

Cisco Transport Manager Release 7.2 User Guide

 

 

 

 

 

 

 

 

 

78-17630-01

 

 

 

D-211

 

 

 

 

 

 

Page 211
Image 211
Cisco Systems 78-17630-01 appendix Transceiver Tab, 211