Appendix D Slot Property
Transponder Cards
Table
Field
Description
Input Power
Value | When the Update button is clicked, displays the current receive transponder input power. |
|
|
Low | Sets the low threshold for the receive transponder input power in dBm and the alarm severity level. |
|
|
High | Sets the high threshold for the receive transponder input power (in dBm) and the alarm severity level. |
|
|
Fail | Sets the failure threshold for the receive transponder input power (in dBm) and the alarm severity level. |
|
|
D.5.13.7 Output Power Tab
The Output Power tab allows you to assign performance monitoring thresholds for the receive transponder output power.
Table
Field
Description
Output Power
Value | When the Update button is clicked, displays the current receive transponder output power. |
|
|
Low | Sets the low threshold for the receive transponder output power (in dB) and the alarm severity level. |
|
|
High | Sets the high threshold for the receive transponder output power (in dB) and the alarm severity level. |
|
|
Fail | Sets the failure threshold for the receive transponder output power (in dB) and the alarm severity level. |
|
|
Note See Table
D.5.14 Slot Properties—Transmitter Transponder
The Slot Properties pane displays information about the Cisco ONS 15808 module that is installed in the slot selected in the NE Explorer tree. Use this properties pane to change the module performance monitoring thresholds.
The transmitter transponder performs 3R regeneration of the 2.5 Gbps and 10 Gbps optical signal and provides client signal validation parameters. The module transposes input client signals to appropriate wavelengths and transmits them to the multiplexing section of the ONS 15808 system. Transmitter transponder modules add
A block diagram is shown in the following figure.
|
| Cisco Transport Manager Release 7.2 User Guide |
|
|
|
|
|
| |||
|
|
|
|
| |
|
|
|
|