Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards

Optical Cards

Table D-146

Field Descriptions for the Line Tab (continued)

 

 

 

 

 

Subfield

 

Description

 

 

 

 

 

Service State

 

Displays the service state:

 

 

 

 

 

IS_NR—In Service–Normal.

 

 

 

 

 

OOS_AU—Out of Service–Autonomous.

 

 

 

 

 

OOS_MA—Out of Service–Management.

 

 

 

 

 

OOS_AUMA—Out of Service–Autonomous and Management.

 

 

 

 

 

In addition, a secondary state provides additional information about the status of the entity.

 

 

 

 

 

Values for secondary state are:

 

 

 

 

 

MEA—Mismatch of equipment due to invalid equipment insertion.

 

 

 

 

 

UEQ—Unequipped; there is nothing in the slot.

 

 

 

 

 

UAS—Unassigned; the entity does not exist, has not been created, or has been deleted.

 

 

 

 

 

SWDL—Software download in progress.

 

 

 

 

 

MT—Maintenance, as per the Admin State change.

 

 

 

 

 

AINS—Automatic in service.

 

 

 

 

 

DSBLD—Traffic is disabled on the entity.

 

 

 

 

 

LPBK—Port or connection has a loopback on it.

 

 

 

 

 

FLT—Fault secondary state. When an entity is faulted, an FLT state is raised. Equipment and

 

 

 

 

 

 

ports in FLT state should be cleared as they transition. Transition states are listed in

 

 

 

 

 

 

Table 11-10 on page 11-15.

 

 

 

 

 

See Table 11-10 on page 11-15for the Service state/Secondary state possible values.

 

 

 

 

 

Note If the NE does not support the Service State, this field shows N/A.

 

 

 

 

 

AINS Soak

 

Automatic in-service soak. The determination of duration left before the traffic/termination

 

 

 

 

 

transitions to IS state.

 

 

 

 

AINS Soak Count Down

Automatic in-service soak countdown. Displays the remaining time of valid input signal in

 

 

 

 

 

hh:mm, after which the card becomes in service (IS) automatically.

 

 

 

 

 

BLSR Ext. Byte

 

Select an alternate BLSR byte. Choices are Z2, E2, or F1.

 

 

 

 

 

 

Line Threshold 15 Minutes

 

 

 

 

 

 

 

 

 

 

Near End

 

 

 

 

 

 

 

 

 

Port Number

 

The optical port number

 

 

 

 

 

ES-L

 

Errored seconds–line

 

 

 

 

 

SES-L

 

Severely errored seconds–line

 

 

 

 

 

CV-L

 

Coding violations–line

 

 

 

 

 

UAS-L

 

Unavailable seconds–line

 

 

 

 

 

FC-L

 

Failure count–line

 

 

 

 

 

PSC

 

Protection switching count—Near-end only

 

 

 

 

 

PSD

 

Protection switching duration—Near-end only

 

 

 

 

 

PSC-W

 

Protection switching count—working

 

 

 

 

 

PSD-W

 

Protection switching duration—working

 

 

 

 

 

 

 

 

Cisco Transport Manager Release 7.2 User Guide

 

 

 

 

D-140

 

 

 

 

78-17630-01

 

 

 

 

 

 

 

Page 140
Image 140
Cisco Systems 78-17630-01 appendix 140