D-169
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards
D.4.15.1 Module View Tab
TheModule View tab displays a graphic of the S1.1-2-LC/E1-21 that is installed in the slot. The number
of critical, major, minor, and warning alarms for the module is displayed under Alarm Status. (Alarms
arealso displayed when you move the mouse pointer over the graphic.) The Suppress Alarms check box
is read-only and indicates whether all alarms are suppressed for the card and its port(s).
D.4.15.2 Identification Tab
The Identification tab allows you to view and update S1.1-2-LC/E1-21 identification information.
D.4.15.3 STM Line Tab
TheSTM Line tab allows you to view and update S1.1-2-LC/E1-21 optical line performance monitoring
information.
TableD-183 Field Descriptions for the Identification Tab
Field Description
Equipment Type Displays the equipment type the slot is provisioned for.
Actual Equipment Type Displays the actual card that is installed in the slot.
HW Part Number Displays the card part number that is printed on the top of the card.
Hardware Revision Displays the hardware version number of the card.
Serial Number Displays the card serial number that is unique to each card.
CLEI Code Displays the CLEI code.
Firmware Version Displays the revision number of the software used by the ASIC chip installed on the card.
Product ID Displays aproduct IDstring of 63 characters maximum. If the card does notsupport the product
ID, the field shows N/A.
Version ID Displays a version ID string in the format “V99_.” The version ID always begins with a V and
ends with a space. If the card does not support the version ID, the field shows N/A.
Equipment State Displays the equipment state of the card.
Alarm Profile Displays the alarm profile for the port.
Suppress Alarms If checked, all alarms are suppressed for the port.
TableD-184 Field Descriptions for the Line Tab
Field Description
Port Number Displays the optical port number.
Port Name Allows you to enter an optical port name.
ProvidesSync If checked, the card is provisioned as an NE timing reference.
EnableSyncMsg Enables synchronization status messages (S1 byte), which allow the node to choose the best timing
source.
Send DoNotUse When checked, sends a DNS (do not use) message on the S1 byte.
Admin State Shows the administrative state of the port: In Service (IS), or Out of Service (OOS).