D-220
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards
Transponder Cards
D.5.2.3 Temperature Tab
The Temperature tab allows you to assign temperature-related thresholds and alarm severities for the
transponder laser.
D.5.2.4 Quality of Service Tab
The Quality of Service tab allows you to assign thresholds and alarm severities for forward error
correction (FEC) counters. Click the 15 min radio buttonto assign thresholds for 15-minute collection
increments. Click the 1 day radio button to assign thresholds for 24-hour collection increments.
TableD-251 Field Descriptions for the Identification Tab
Field Description
NE ID Displays the user-defined name of the NE where the transponder is installed.
Description Displays information that a user has entered (if any) to describe the NE.
NE Model Identifies the model of the selected NE (ONS 15800 or ONS 15801) where the transponder is
installed.
Rack ID Displays the identification number of the rack where the subrack containing the transponder is
installed.
Subrack ID Displays the identification number of the subrack.
Slot ID Displays the identification number of the slot containing the transponder.
Software Version Displays the version of the software running on the module.
BIOS Version Displays the version number of the BIOS.
Board Serial Number Displays the serial number of the board.
SCC Number Displays the version of the module serial communication controller (SCC).
Product Option Displays the product option. Displays “Not Available” if TL1 Agent version is earlier than
version 2.1.
Hardware Version Displays the versionof thehardware. Displays“Not Available”if TL1Agent versionis earlier
than version 2.1.
Line Direction Shows the line direction for the transponder.
State Allows you to place the transponder in one of two states: In Service or Under Maintenance.
PM Collection Status Allows you to enable or disable PM data collection for the transponder.
TableD-252 Field Descriptions for the Temperature Tab
Field Description
Value When the Update button is clicked, displays the current temperature of Laser 1.
Low Sets the low temperature threshold (in degrees Celsius) and the alarm severity level.
High Sets the high temperature threshold (in degrees Celsius) and the alarm severity level.