Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards

Transponder Cards

Table D-278

Field Descriptions for the Identification Tab

 

 

 

Field

 

Description

 

 

 

NE ID

 

Displays the user-defined name of the NE where the transponder is installed.

 

 

 

Description

 

Displays information that a user has entered (if any) to describe the NE.

 

 

 

NE Model

 

Identifies the model of the selected NE (ONS 15800 or ONS 15801) where the transponder is

 

 

installed.

 

 

 

Rack ID

 

Displays the identification number of the rack where the subrack containing the transponder is

 

 

installed.

 

 

 

Subrack ID

 

Displays the identification number of the subrack.

 

 

 

Slot ID

 

Displays the identification number of the slot containing the transponder.

 

 

Software Version

Displays the version of the software.

 

 

 

BIOS Version

 

Displays the version number of the BIOS.

 

 

Board Serial Number

Displays the serial number of the board.

 

 

 

SCC Number

 

Displays the version of the module serial communication controller (SCC).

 

 

 

Product Option

 

Displays the product option. Displays “Not Available” if the TL1 Agent version is earlier than

 

 

version 2.1.

 

 

Hardware Version

Displays the version of the hardware. Displays “Not Available” if the TL1 Agent version is

 

 

earlier than version 2.1.

 

 

 

Line Direction

 

Shows the line direction for the transponder.

 

 

 

State

 

Allows you to place the transponder in one of two states: In Service or Under Maintenance.

 

 

PM Collection Status

Allows you to enable or disable PM data collection for the transponder.

 

 

 

D.5.6.3 Temperature Tab

 

The Temperature tab allows you to assign performance monitoring thresholds for the transponder laser

 

temperature.

Table D-279

Field Descriptions for the Temperature Tab

 

 

Field

Description

 

 

Value

When the Update button is clicked, displays the current temperature of Laser 1.

 

 

Low

Sets the low temperature threshold (in degrees Celsius) and the alarm severity level.

 

 

High

Sets the high temperature threshold (in degrees Celsius) and the alarm severity level.

 

 

D.5.6.4 Quality of Service Tab

The Quality of Service tab allows you to assign thresholds and alarm severities for B1 counters. Click the 15 min radio button to assign thresholds for 15-minute collection increments. Click the 1 day radio button to assign thresholds for 24-hour collection increments.

 

 

Cisco Transport Manager Release 7.2 User Guide

 

 

 

 

 

 

 

78-17630-01

 

 

D-233

 

 

 

 

 

Page 233
Image 233
Cisco Systems 78-17630-01 appendix Temperature Tab, 233