D-237
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards
D.5.7.3 Temperature Tab
The Temperature tab allows you to assign performance monitoring thresholds for the transponder
operating temperature.
D.5.7.4 Quality of Service Tab
The Quality of Service tab allows you to assign thresholds and alarm severities for forward error
correction (FEC) counters. Click the 15 min radio buttonto assign thresholds for 15-minute collection
increments. Click the 1 day radio button to assign thresholds for 24-hour collection increments.
Software Version Displays the version of the software.
BIOS Version Displays the version number of the BIOS.
Board Serial Number Displays the serial number of the board.
SCC Number Displays the version of the module serial communication controller (SCC).
Product Option Displays the product option. Displays Not Available if TL1 Agent version is earlier than version
2.1.
Hardware Version Displaysthe versionof thehardware. DisplaysNot Available if TL1Agent version is earlier than
version 2.1.
Line Direction Shows the line direction for the transponder.
State Allows you to place the transponder in one of two states: In Service or Under Maintenance.
PM Collection Status Allows you to enable or disable PM collection for the transponder.
TableD-285 Field Descriptions for the Identification Tab (continued)
Field Description
TableD-286 Field Descriptions for the Temperature Tab
Field Description
Laser 1
Value When the Update button is clicked, displays the current temperature of Laser 1 (in degrees Celsius).
Low Sets the operating temperature low threshold, in degrees Celsius, and the alarm severity level.
High Sets the operating temperature high threshold, in degrees Celsius, and the alarm severity level.
TableD-287 Field Descriptions for the Quality of Service Tab
Field Description
FEC Counters
Errored Seconds Sets the high threshold for the number of FEC errored seconds (ES) and the alarm severity
level. An errored second is a one-second period with one or more error blocks or at least one
defect.
Severely Errored Seconds Sets the high threshold for the number of FEC severely errored seconds (SES) and the alarm
severity level. A severely errored second is a one-second period that contains at least 30%
errored blocks or at least one defect.