D-245
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards
D.5.9.3 Current Tab
The Current tab allows you to assign performance monitoring thresholds for the receive transponder
Laser 1 current levels.
D.5.9.4 Power Tab
ThePower tab allows you to assign performance monitoring thresholds for the receive transponder Laser
1 power levels.
Slot ID Displays the identification number of the slot containing the receive transponder.
Software Version Displays the version of the software.
BIOS Version Displays the version number of the BIOS.
Board Serial Number Displays the serial number of the board.
SCC Number Displays the version of the module serial communication controller (SCC).
Product Option Displaysthe productoption.Displays “NotAvailable”if theTL1Agent versionisearlier thanversion
2.1.
Hardware Version Displays the version of the hardware. Displays “Not Available” if the TL1 Agent version is earlier
than version 2.1.
Line Direction Shows the line direction for the receive transponder.
State Allows you to place the receive transponder in one of two states: In Service or Under Maintenance.
PM Collection Status Allows you to enable or disable PM data collection for the receive transponder.
TableD-299 Field Descriptions for the Identification Tab (continued)
Field Description
TableD-300 Field Descriptions for the Current Tab
Field Description
Laser 1 Current
Value When theUpdate button is clicked, displays the current of the receive transponder.
Degrade Sets the degrade threshold for the Laser 1 current (in mA) and the alarm severity level.
Fail Sets the failure threshold for the Laser 1 current (in mA) and the alarm severity level.
TableD-301 Field Descriptions for the Power Tab
Field Description
Laser 1 Power
Value When the Update button is clicked, displays the current power of Laser 1.
Low Sets the low threshold for the Laser 1 power (in mW) and the alarm severity level.
High Sets the high threshold for the Laser 1 power (in mW) and the alarm severity level.