Appendix D Slot Property
Transponder Cards
Table | Field Descriptions for the Quality of Service Tab | |
|
|
|
Field |
| Description |
|
|
|
Errored Seconds |
| Sets the high threshold for the number of B1 errored seconds (ES) and the alarm severity level. |
|
| An errored second is a |
|
| |
Severely Errored Seconds | Sets the high threshold for the number of B1 severely errored seconds (SES) and the alarm | |
|
| severity level. A severely errored second is a |
|
| percent of errored blocks or at least one defect. |
|
| |
Background Block Errors | Sets the high threshold for the number of B1 background block errors (BBE) and the alarm | |
|
| severity level. An errored block is a block in which one or more bits are in error. A background |
|
| block error is an errored block that does not occur as part of a severely errored second. |
|
| |
Unavailable Seconds | Sets the high threshold for the number of B1 unavailable seconds (UAS) and the alarm severity | |
|
| level. The detection of 10 consecutive SES begins a period of UAS. The 10 SES detected are |
|
| part of the UAS. The ES and SES counters decrement by 10 seconds and the UAS counter |
|
| increments by an equivalent number of seconds. A new period of available time begins at the |
|
| onset of 10 consecutive |
|
|
|
D.5.6.5 Current Tab
The Current tab allows you to assign performance monitoring thresholds for the transponder laser current levels.
Table
Field | Description |
|
|
Value | When the Update button is clicked, displays the current value of the transponder laser current. |
|
|
Degrade | Sets the degrade threshold for the laser current (in mA) and the alarm severity level. |
|
|
Fail | Sets the failure threshold for the laser current (in mA) and the alarm severity level. |
|
|
D.5.6.6 Power Tab
The Power tab allows you to assign performance monitoring thresholds for the transponder Laser 1 power levels.
Table
Field | Description |
|
|
Value | When the Update button is clicked, displays the current power of Laser 1. |
|
|
Low | Sets the low threshold for the laser power (in mW) and the alarm severity level. |
|
|
High | Sets the high threshold for the laser power (in mW) and the alarm severity level. |
|
|
D.5.6.7 Input Power Tab
The Input Power tab allows you to assign performance monitoring thresholds for the power coming into the transponder.
| Cisco Transport Manager Release 7.2 User Guide |
|