Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards

Transponder Cards

Table D-259

Field Descriptions for the Identification Tab (continued)

 

 

 

Field

 

Description

 

 

 

Slot ID

 

Displays the identification number of the slot containing the transponder.

 

 

Software Version

Displays the version of the software running on the module.

 

 

 

BIOS Version

 

Displays the version number of the BIOS.

 

 

Board Serial Number

Displays the serial number of the board.

 

 

 

SCC Number

 

Displays the version of the module serial communication controller (SCC).

 

 

 

Product Option

 

Displays the product option. Displays “Not Available” if TL1 Agent version is earlier than version

 

 

2.1.

 

 

Hardware Version

Displays the version of the hardware. Displays “Not Available” if TL1 Agent version is earlier than

 

 

version 2.1.

 

 

 

Line Direction

 

Shows the line direction for the transponder.

 

 

 

State

 

Allows you to place the transponder in one of two states: In Service or Under Maintenance.

 

 

PM Collection Status

Allows you to enable or disable PM data collection for the transponder.

 

 

 

D.5.3.3 Temperature Tab

The Temperature tab allows you to assign thresholds and alarm severities for the transponder laser.

Table D-260 Field Descriptions for the Temperature Tab

Field

Description

 

 

Value

When the Update button is clicked, displays the current temperature of the transponder laser.

 

 

Low

Sets the low temperature threshold (in degrees Celsius) and the alarm severity level.

 

 

High

Sets the high temperature threshold (in degrees Celsius) and the alarm severity level.

 

 

D.5.3.4 Current Tab

 

The Current tab allows you to assign thresholds and alarm severities for the transponder laser current

 

levels.

Table D-261

Field Descriptions for the Current Tab

 

 

Field

Description

 

 

Value

When the Update button is clicked, displays the current value of the laser current.

 

 

Degrade

Sets the degrade threshold for the laser current (in mA) and the alarm severity level.

 

 

Fail

Sets the failure threshold for the laser current (in mA) and the alarm severity level.

 

 

D.5.3.5 Power Tab

The Power tab allows you to assign thresholds and alarm severities for the transponder Laser 1 power levels.

 

Cisco Transport Manager Release 7.2 User Guide

D-224

78-17630-01

Page 224