Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards

Transponder Cards

Note See Table 1-20 on page 1-44for descriptions of actions that can be performed using the buttons at the bottom of the window.

D.5.13 Slot Properties—RXT-FEC

The Slot Properties pane displays information about the Cisco ONS 15800 or ONS 15801 module that is installed in the slot selected in the NE Explorer tree. Use this properties pane to change the module performance monitoring thresholds.

Receive transponder-forward error correction (RXT-FEC) modules are used in ONS 15800 and ONS 15801 terminal sites to retime, reshape, and regenerate low input demultiplexed signals.

RXT modules shown on this sheet include:

Receive Transponder–Directly Modulated–Forward Error Correction (RXT-DM-F) 2.5 Gbps module

Receive Transponder–10 Gbps–Forward Error Correction (RXT-10G-F) module

For FEC RXT modules, the Slot Properties pane displays the following tabs: Module View,

Identification, Quality of Service, Current, Power, Input Power, and Output Power.

D.5.13.1 Module View Tab

The Module View tab displays a graphic of the transponder that is installed in the slot. The number of critical, major, minor, and warning alarms for the module is displayed under Alarm Status. (Moving the mouse pointer over the graphic also displays the alarm counts.) The module status is displayed under Operational State. Right-clicking the graphic opens a shortcut menu that you can use to display the module in the Alarm Browser, in the Equipment Inventory Table, or in the FEC RXT PM Table.

D.5.13.2 Identification Tab

 

 

 

 

 

The Identification tab allows you to view and update receive transponder identification information.

Table D-321

Field Descriptions for the Identification Tab

 

 

 

 

 

 

Field

 

 

Description

 

 

 

 

 

 

NE ID

 

 

Displays the user-defined name of the NE where the receive transponder is installed.

 

 

 

 

 

 

Description

 

 

Displays information that a user has entered (if any) to describe the NE.

 

 

 

 

 

 

NE Model

 

 

Identifies the model of the selected NE (ONS 15800 or ONS 15801) where the receive transponder

 

 

 

 

 

 

is installed.

 

 

 

 

 

 

Rack ID

 

 

Displays the identification number of the rack where the subrack containing the receive

 

 

 

 

 

 

transponder is installed.

 

 

 

 

 

 

Subrack ID

 

 

Displays the identification number of the subrack containing the receive transponder.

 

 

 

 

 

 

Slot ID

 

 

Displays the identification number of the slot containing the receive transponder.

 

 

 

 

 

Software Version

 

Displays the version of the software.

 

 

 

 

 

BIOS Version

 

Displays the version number of the BIOS.

 

 

 

 

 

Board Serial Number

 

Displays the serial number of the board.

 

 

 

 

 

 

 

 

 

 

Cisco Transport Manager Release 7.2 User Guide

 

 

 

 

 

D-256

 

 

 

78-17630-01

 

 

 

 

 

 

Page 256
Image 256
Cisco Systems 78-17630-01 appendix Slot Properties-RXT-FEC, 256