D-256
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards
Transponder Cards
Note See Table1-20 on page 1-44 for descriptions of actions that can be performed using the buttons at the
bottom of the window.
D.5.13 Slot Properties—RXT-FEC
The Slot Properties pane displays information about the Cisco ONS 15800 or ONS 15801 module that
is installed in the slot selected in the NE Explorer tree. Use this properties pane to change the module
performance monitoring thresholds.
Receive transponder-forward error correction (RXT-FEC) modules are used in ONS 15800 and
ONS 15801 terminal sites to retime, reshape, and regenerate low input demultiplexed signals.
RXT modules shown on this sheet include:
Receive Transponder–Directly Modulated–Forward Error Correction (RXT-DM-F) 2.5 Gbps
module
Receive Transponder–10 Gbps–Forward Error Correction (RXT-10G-F) module
For FEC RXT modules, the Slot Properties pane displays the following tabs: Module View,
Identification, Quality of Service, Current, Power, Input Power, and Output Power.

D.5.13.1 Module View Tab

The Module View tab displays a graphic of the transponder that is installed in the slot. The number of
critical,major, minor, and warning alarms for the module is displayed under Alarm Status. (Moving the
mouse pointer over the graphic also displays the alarm counts.) The module status is displayed under
Operational State. Right-clicking the graphic opens a shortcut menu that you can use to display the
module in the Alarm Browser, in the Equipment Inventory Table, or in the FEC RXT PM Table.

D.5.13.2 Identification Tab

The Identification tab allows you to view and update receive transponder identification information.
TableD-321 Field Descriptions for the Identification Tab
Field Description
NE ID Displays the user-defined name of the NE where the receive transponder is installed.
Description Displays information that a user has entered (if any) to describe the NE.
NE Model Identifiesthe model of the selected NE (ONS 15800or ONS 15801) where the receive transponder
is installed.
Rack ID Displays the identification number of the rack where the subrack containing the receive
transponder is installed.
Subrack ID Displays the identification number of the subrack containing the receive transponder.
Slot ID Displays the identification number of the slot containing the receive transponder.
Software Version Displays the version of the software.
BIOS Version Displays the version number of the BIOS.
Board Serial Number Displays the serial number of the board.