Appendix D Slot Property
Transponder Cards
Table | Field Descriptions for the Power Tab |
|
|
Field | Description |
|
|
Value | When the Update button is clicked, displays the current power of Laser 1. |
|
|
Low | Sets the low threshold for the laser power (in mW) and the alarm severity level. |
|
|
High | Sets the high threshold for the laser power (in mW) and the alarm severity level. |
|
|
D.5.3.6 Input Power Tab
| The Input Power tab allows you to assign thresholds and alarm severities for the power coming into the |
| transponder. |
Table | Field Descriptions for the Input Power Tab |
|
|
Field | Description |
|
|
Value | When the Update button is clicked, displays the current transponder input power. |
|
|
Low | Sets the low threshold for the module input power in dBm and the alarm severity level. |
|
|
High | Sets the high threshold for the module input power (in dBm) and the alarm severity level. |
|
|
D.5.3.7 Output Power Tab
| The Output Power tab allows you to assign thresholds and alarm severities for the transponder output |
| power. |
Table | Field Descriptions for the Output Power Tab |
|
|
Field | Description |
|
|
Value | When the Update button is clicked, displays the current transponder output power. |
|
|
Low | Sets the low threshold for the transponder output power (in dBm) and the alarm severity level. |
|
|
High | Sets the high threshold for the transponder output power (in dBm) and the alarm severity level. |
|
|
Note See Table
D.5.4 Slot Properties—LEM-10-B1
The Slot Properties pane displays information about the Cisco ONS 15800 or ONS 15801 module that is installed in the slot selected in the NE Explorer tree. Use this properties pane to change the module performance monitoring thresholds.
Line extender modules (LEMs) extend transmission distances in ONS 15800 or ONS 15801 regeneration and optical add/drop multiplexing (OADM) sites.
A block diagram is shown is the following figure.
|
| Cisco Transport Manager Release 7.2 User Guide |
|
|
|
|
|
| |||
|
|
|
|
| |
|
|
|
|