D-52
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards
Multirate Cards
AINS Soak Count Down (H:M) Automatic in-service soak countdown. Displaysthe remaining time of valid inputsignal
in hh:mm, after which the card becomes in service (IS) automatically.
Admin SSM If the node does not receive an SSM signal, it defaults to STU (synchronization
traceabilityunknown). Admin SSM allows you to override the STU value with one of the
following:
•PRS—Primary reference source (Stratum 1)
•STS2—Stratum 2
•TNC—Transit node clock
•STS3E—Stratum 3E
•STS3—Stratum 3
•SMC—SONET minimum clock
•ST4—Stratum 4
Send <FF> DoNotUse When checked, sends a special do not use (DUS) (0xff) message on the S1 byte.
PJ VC-4 Mon# Setsthe VCthat willbeused forpointer justification.If setto 0,noVC ismonitored. Only
one VC can be monitored on each STM port.
TableD-59 Field Descriptions for the Line Config Subtab (continued)
Field Description