D-271
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards
D.5.17.3 Temperature Tab
The Temperature tab allows you to assign performance monitoring thresholds for the wavelength
converter module laser temperature.
D.5.17.4 Quality of Service Tab
TheQuality of Service tab allows you to assign thresholds and alarm severities for B1 and FEC counters.
Clickthe 15 min radio button to assign thresholds for 15-minute collection increments. Click the 1 day
radio button to assign thresholds for 24-hour collection increments.
TableD-347 Field Descriptions for the Identification Tab
Field Description
NE ID Displays the user-defined name of the NE where the wavelength converter module is installed.
Description Displays information that a user has entered (if any) to describe the NE.
NE Model Identifies the model of the selected NE (ONS 15800 or ONS 15801) where the wavelength converter
module is installed.
Rack ID Displaysthe identificationnumber ofthe rack wherethe subrackcontaining thewavelength converter
module is installed.
Subrack ID Displays the identification number of the subrack containing the wavelength converter module.
Slot ID Displays the identification number of the slot containing the wavelength converter module.
Software Version Displays the version of the software.
BIOS Version Displays the version number of the BIOS.
Board Serial
Number Displays the serial number of the board.
SCC Number Displays the version of the module serial communication controller (SCC).
Product Option Displaysthe product option. Displays“Not Available” if the TL1 Agentversion is earlier than version
2.1.
Hardware Version Displaysthe version ofthe hardware. Displays“Not Available”if the TL1Agent version is earlier than
version 2.1.
Line Direction Shows the line direction for the wavelength converter module.
State Allows you to place the wavelength converter module in one of two states: In Service or Under
Maintenance.
PM Collection
Status Allows you to enable or disable PM data collection for the wavelength converter module.
TableD-348 Field Descriptions for the Temperature Tab
Field Description
Laser 1 Temperature
Value When theUpdate button is clicked, displays the current temperature of Laser 1.
Low Sets the low temperature threshold for Laser 1 (in degrees Celsius) and the alarm severity level.
High Sets the high temperature threshold for Laser 1 (in degrees Celsius) and the alarm severity level.