Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards

Transponder Cards

D.5.19.6 Power Tab

The Power tab allows you to assign performance monitoring thresholds for the wavelength converter module Laser 1 power levels.

Table D-367 Field Descriptions for the Power Tab

Field

Description

Laser 1 Power

Value

When the Update button is clicked, displays the current power of Laser 1.

 

 

Low

Sets the low threshold for the laser power (in mW) and the alarm severity level.

 

 

High

Sets the high threshold for the laser power (in mW) and the alarm severity level.

 

 

D.5.19.7 Input Power Tab

The Input Power tab allows you to assign performance monitoring thresholds for the power coming into the module.

Table D-368 Field Descriptions for the Input Power Tab

Field

Description

Input Power 1

Value

When the Update button is clicked, displays the current wavelength converter module input power.

 

 

Low

Sets the low threshold for the module input power in dBm and the alarm severity level.

 

 

High

Sets the high threshold for the module input power (in dBm) and the alarm severity level.

 

 

D.5.19.8 Output Power Tab

The Output Power tab allows you to assign performance monitoring thresholds for the module output power.

Table D-369 Field Descriptions for the Output Power Tab

Field

Description

Output Power 1

Value

When the Update button is clicked, displays the current wavelength converter module output power.

 

 

Low

Sets the low threshold for the module Laser 1 output power (in dBm) and the alarm severity level.

 

 

High

Sets the high threshold for the module Laser 1 output power (in dBm) and the alarm severity level.

 

 

Note See Table 1-20 on page 1-44for descriptions of actions that can be performed using the buttons at the bottom of the window.

 

Cisco Transport Manager Release 7.2 User Guide

D-282

78-17630-01

Page 282
Image 282
Cisco Systems 78-17630-01 appendix Power Tab, 282