Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards

Optical Cards

Table D-106

Field Descriptions for the Identification Tab (continued)

 

 

 

Field

 

Description

 

 

Administration State

The port administration state. It can be:

 

 

IS—In Service.

 

 

IS, AINS—Automatic In Service.

 

 

OOS, DSBLD—Out of Service, Disabled.

 

 

OOS, MT—Out of Service, Maintenance.

 

 

 

Service State

 

Overall availability of the entity. Values are:

 

 

IS_NR—In Service–Normal.

 

 

OOS_AU—Out of Service–Autonomous.

 

 

OOS_MA—Out of Service–Management.

 

 

OOS_AUMA—Out of Service–Autonomous and Management.

 

 

In addition, a secondary state provides additional information about the status of the entity.

 

 

Values for secondary state are:

 

 

MEA—Mismatch of equipment due to invalid equipment insertion.

 

 

UEQ—Unequipped. There is nothing in the slot.

 

 

UAS—Unassigned. The entity does not exist, has not been created, or has been deleted.

 

 

SWDL—Software download in progress.

 

 

MT—Maintenance, as per the Admin State change.

 

 

AINS—Automatic In Service.

 

 

DSBLD—Traffic is disabled on the entity.

 

 

LPBK—Port or connection has a loopback on it.

 

 

FLT—Fault secondary state. When an entity is faulted, an FLT state is raised. Equipment

 

 

 

and ports in FLT state should be cleared as they transition. Transition states are listed in

 

 

 

Table 11-10 on page 11-15.

 

 

See Table 11-10 on page 11-15for the Service state/Secondary state possible values.

 

 

Note If the NE release does not support the Service state, this field shows N/A.

 

 

 

Equipment State

 

Displays the equipment state of the card.

 

 

 

Alarm Profile

 

Sets the alarm profile for the port. Check the Suppress Alarms check box to suppress all

 

 

alarms for this card and its port(s).

 

 

 

 

D.4.4.3 Pluggable Provisioning Tab

The Pluggable Provisioning tab allows you to view and provision pluggable entities; for example, the pluggable port module (PPM) and the ports inside these entities.

Table D-107 Field Descriptions for the Pluggable Provisioning Tab

 

Field

Description

 

 

 

 

Pluggable Number

Displays the identifier of the plugin module.

 

 

 

 

Actual Equipment Type

Displays the actual card that is installed in the slot.

 

 

 

 

 

 

 

 

Cisco Transport Manager Release 7.2 User Guide

 

 

 

 

D-94

 

 

78-17630-01

 

 

 

 

 

Page 94
Image 94
Cisco Systems 78-17630-01 appendix Pluggable Provisioning Tab