D-167
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards
D.4.14.6 Protection Tab
The Protection tab allows you to view and update STM-1 protection group information.
D.4.14.7 Alarm Behavior Tab
The Alarm Behavior tab allows you to view and update STM-1 alarm profile information.
D.4.14.8 Auto Laser Shutdown Tab
The Auto Laser Shutdown tab allows you to view and update ALS parameters.
TableD-179 Field Descriptions for the Protection Tab
Field Description
Protection Groups Displays a list of available protection groups.
Protection Group Details Displays details about the selected protection group.
TableD-180 Field Descriptions for the Alarm Behavior Tab
Field Description
Alarm Profile Displays the alarm profile that has been configured for the card.
Suppress Alarms If checked, indicates that all alarms are suppressed for the card.
Port Number Displays the card port number.
Alarm Profile Choose an alarm profile for the port from the drop-down list. Values are Default, Inherited, or a
customized alarm profile.
Suppress Alarms If checked, all alarms are suppressed for the port.
Alarm Profile Choose an alarm profile for all ports.
Force to All Ports When clicked, forces all the ports to the selected alarm profile.
TableD-181 Field Descriptions for the Auto Laser Shutdown Tab
Field Description
Port No. Displays the port number.
ALS Mode Displays the auto laser shutdown mode (Disabled, Auto Restart, Manual Restart, or Manual
Restart for Test).
Rec. Pulse Dur. (sec) Allows youto set the received laser pulse duration, in seconds. The rangeis 2.0 to 100.0 seconds.
Rec. Pulse Int. (sec) Allows you to set the received laser pulse interval, in seconds. The range is 60 to 300 seconds.
Status Displays the current laser status. Values are Shutdown or Not Shutdown.
Request Restart If selected, it allows you to request a laser restart. This parameter is configurable only when the
ALS mode is set to Manual Restart or Manual Restart for Test and when the laser status is Shut
Down.