Appendix D Slot Property
Transponder Cards
Table
Field
Description
Input Power
Value | When the Update button is clicked, displays the current receive transponder input power. |
|
|
Fail | Sets the fail threshold for the receive transponder input power (in dBm) and the alarm severity level. |
|
|
Degrade | Sets the degrade threshold for the receive transponder input power (in dBm) and the alarm severity level. |
|
|
D.5.11.7 Output Power Tab
The Output Power tab allows you to assign performance monitoring thresholds for the receive transponder output power.
Table
Field
Description
Output Power
Value | When the Update button is clicked, displays the current receive transponder output power. |
|
|
Low | Sets the low threshold for the receive transponder output power (in dBm) and the alarm severity level. |
|
|
High | Sets the high threshold for the receive transponder output power (in dBm) and the alarm severity level. |
|
|
Note See Table
D.5.12 Slot Properties—RXT-B1
The Slot Properties pane displays information about the Cisco ONS 15800 or ONS 15801 module that is installed in the slot selected in the NE Explorer tree. Use this properties pane to change the module performance monitoring thresholds.
ONS 15800 and ONS 15801 receive transponder (RXT) modules are used in ONS 15800 and ONS 15801 terminal sites to retime, reshape, and regenerate low input demultiplexed signals.
A block diagram is shown in the following figure.
| Cisco Transport Manager Release 7.2 User Guide |
|