D-252
Cisco Transport Manager Release 7.2 User Guide
78-17630-01
AppendixD Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards
Transponder Cards

D.5.11.7 Output Power Tab

The Output Power tab allows you to assign performance monitoring thresholds for the receive
transponder output power.
Note See Table1-20 on page 1-44 for descriptions of actions that can be performed using the buttons at the
bottom of the window.
D.5.12 Slot Properties—RXT-B1
The Slot Properties pane displays information about the Cisco ONS 15800 or ONS 15801 module that
is installed in the slot selected in the NE Explorer tree. Use this properties pane to change the module
performance monitoring thresholds.
ONS15800 and ONS 15801 receive transponder (RXT) modules are used in ONS 15800 and ONS 15801
terminal sites to retime, reshape, and regenerate low input demultiplexed signals.
A block diagram is shown in the following figure.
TableD-313 Field Descriptions for the Input Power Tab
Field Description
Input Power
Value When the Update button is clicked, displays the current receive transponder input power.
Fail Sets the fail threshold for the receive transponder input power (in dBm) and the alarm severity level.
Degrade Sets the degrade threshold for the receive transponder input power (in dBm) and the alarm severity level.
TableD-314 Field Descriptions for the Output Power Tab
Field Description
Output Power
Value When the Update button is clicked, displays the current receive transponder output power.
Low Sets the low threshold for the receive transponder output power (in dBm) and the alarm severity level.
High Sets the high threshold for the receive transponder output power (in dBm) and the alarm severity level.