Start
End
Is the LED on the power
supply unit off?
Check the connection of the power
supply unit and power cords.
YES
NO
NO
YES
Was e-mail sent by the
XSCF mail function?
Check /var/adm/messages on
Oracle Solaris.
Write down the displayed failure
information.
Contact our service engineer.
Confirm that an error message is
displayed on the OS and XSCF
consoles.
Execute showlogs on XSCF to
display failure information.

Figure3-1 Troubleshooting flow

3.3 Identifying a Failure

Thissection explains the method for identifying a failure. Use the flow describedin

"3.2 Determiningthe Causes of Individual Failures" to determine the appropriate

way of checking for a failure.

FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual December 201334