Appendix

SNTP

The printer clock can be synchronized with a NTP server clock using the Simple Network Time Protocol (SNTP). To change the SNTP settings, use the sntp com- mand. Confirm with the network administrator that the NTP server settings are correct.

Limitation

SNTP supports the NTP servers running xnptd V3 and V4.

Reference msh> sntp

NTP Server Address Configuration

You can specify the IP address of the NTP server. msh> sntp server IP_address

Interval Configuration

You can specify the interval at which the printer synchronizes with the oper- ator-specified NTP server.

msh> sntp interval polling_time

Note

The factory default setting is 3600 seconds.

 

You can set the interval from 16 to 16384 seconds.

7

If you set 0, the printer synchronizes with the NTP server only when you turn the printer on. After that, the printer does not synchronize with the NTP server.

Time-zone Configuration

You can specify the time difference between the printer clock and the NTP server clock.

msh> sntp timezone +/-hour_time

Example: To set the time-zone difference to +8 hours: msh> sntp timezone +08:00

Note

The time is in 24-hour notation.