Table 2 Date and Time panel fields (Sheet 2 of 2)

 

 

 

Attribute

Value

Description

 

 

 

Synch every (s)

NA (not applicable)

The number of seconds specified to elapse between contacts

 

1-XXXX

with the NTP server.

 

NA: Appears if you chose Manually in the Synch with Server

 

 

 

 

field.

 

 

1-XXXX: Number of seconds between contacts with the NTP

 

 

server.

 

 

 

NTP security mode

Secured

Select whether the NTP security mode is secured or

 

Unsecured

unsecured.

 

 

 

 

 

Raise Alarm if Clock differs

<seconds>

The number of discrepancy seconds specified that must occur

by at least (s)

 

before the system notifies you of a time difference from the

 

 

NTP server, if the system automatically checks with the NTP

 

 

server.

 

 

 

NTP key ID

<1-65,534>

ID for accessing the NTP.

 

 

 

NTP key string

<8 characters>

Control key corresponding to ID for accessing the NTP.

 

 

 

Current Date and Time

 

 

 

 

 

Date and time

<country/

The current date and time.

 

region-specific date

 

 

and time format>

 

 

 

 

Year

<numeric>

The current year in yyyy format.

 

 

 

Time zone

<drop-down list>

The appropriate time zone for the location of this system. The

 

 

Time zone must be set for software updates to be applied.

 

 

 

Daylight Savings Time

<read-only>

The appropriate mode for the Time zone.

 

 

Selected: The system automatically updates the time twice a

 

 

year.

 

 

Cleared: The system never updates the time for Daylight

 

 

Savings Time.

 

 

 

Note: North American Daylight Savings Time rules change in 2007. Four time zones have been added to support regions that do not want to switch to the new time zone rules. The time zones are identified “pre-2007 DST”.

If the system is to synchronize with an NTP Server or trunk, check the following:

1Set Date and Time Source to NTP or Trunk.

2In the NTP server address field enter the IP address of the NTP server.

3Set the number of seconds between synchronizations in normal operations (Synch Every).

BCM 4.0 Device Configuration Guide