Ethernet OAM
Ethernet OAM Settings
This window is used to configure the ports Ethernet OAM mode. In Active mode the ports can initiate OAM discovery and start or stop remote loopback. When a port in OAM enabled, any change to the OAM mode will cause the OAM discovery to be restarted.
To view this window, click L2 Features > Ethernet OAM > Ethernet OAM Settings as shown below:
| Figure 3 - 85 Ethernet OAM Settings window |
The following parameters can be configured: | |
|
|
Parameter | Description |
|
|
From Port / To Port | Specify a range of ports to be configured. |
|
|
Mode | Specify to operate in either Active mode or Passive mode The default mode is Active. |
|
|
State | Specify that the OAM function state is Enabled or Disabled. The default state is Disabled. |
|
|
Remote Loopback | Specify to Start or Stop the OAM remote loopback function. |
|
|
Received Remote | Specify whether to Process or to Ignore the received Ethernet OAM remote loopback |
Loopback | function. The default method is Ignore. |
|
|
Click Apply to implement changes.