Ethernet OAM Configuration Settings
This window is used to configure and display the primary controls and status information for Ethernet OAM on the Switch.
To view this window, click L2 Features > Ethernet OAM > Ethernet OAM Configuration Settings as shown below:
| Figure 3 - 86 Ethernet OAM Configuration Settings window |
The following parameters can be configured: | |
|
|
Parameter | Description |
|
|
From Port / To Port | Specify a range of ports to be configured. |
|
|
Link Event | Configures the Ethernet OAM critical link event. Specify Link Monitor or Critical Link Event. |
|
|
Link Monitor | Indicates that the OAM entity can send and receive Event Notification OAMPDUs. |
|
|
Threshold | Specify the number of error frame seconds in the period that is required to be equal to or |
| greater than in order for the event to be generated. The default value of threshold is 1 error |
| frame second. |
Window | Specify the period of error frame summary events. The range is |
default value is 1000 ms. | |
|
|
Notify | Specify to Enable or Disable the event notification. The default state is Enabled. |
|
|
Click Apply to implement changes.
129