System Severity Settings
The Switch can be configured to allow alerts be logged or sent as a trap to an SNMP agent or both. The level at which the alert triggers either a log entry or a trap message can be set as well. Use the System Severity Settings menu to set the criteria for alerts. The current settings are displayed below the Settings menu.
To view this window, click Configuration > System Severity Settings as shown below:
| Figure 2 - 19 System Severity Settings |
Use the | |
|
|
Parameter | Description |
|
|
System Severity | Choose how the alerts are used from the |
| Severity Type configured to the Switch’s log for analysis. Choose trap to send it to an SNMP |
| agent for analysis. Select all to send the chosen alert type to an SNMP agent and the |
| Switch’s log for analysis. |
|
|
Severity Level | Choose what level of alert will trigger sending the log entry or trap message as defined by the |
| Severity Name. Select critical to send only critical events to the Switch’s log or SNMP agent. |
| Choose warning to send critical and warning events to the Switch’s log or SNMP agent. |
| Select information to send informational, warning and critical events to the Switch’s log or |
| SNMP agent. |
|
|
Click Apply to implement the new System Severity Settings.